Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 18 (64.4) 18 (64.4) 16 (60.8) 15 (59 DEG C (DEG F)
AAT_V AAT Sensor 2.97 2.97 3.17 3.21 VOLTS
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 9 23 %
APP1 APP Sensor 0.82 0.82 1.11 1.53 VOLTS
APP1 APP Sensor 16 16 22 30 %
(APP_D)            
APP2 APP Sensor 0.42 0.42 0.56 0.78 VOLTS
APP2 (APP_E) APP Sensor 8 8 11 15 %
APP_MAXDIFF PID 0 0 0 0 DEG
BARO PID 100 (14.50) 100 (14.50) 100 (14.50) 100 (14.50) kPa (PSI)
BARO_V PID 3.93 3.94 3.94 3.94 VOLTS
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 4 4 5 5 NUMERIC VALUE
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
CAM_SYNC PID NO NO NO NO YES/NO
CATEMP11 CAT11 Sensor 326 (618.8) 301 (573.8) 351 (663.8) 412 (773.6) DEG C (DEG F)
CATEMP21 CAT21 Sensor 326 (618.8) 301 (573.8) 351 (663.8) 412 (773.6) DEG C (DEG F)
CHT CHT Sensor 100 () 95 (203) 95 (203) 99 (210.2) DEG C (DEG F)
CHT_V CHT Sensor 3.39 3.54 3.54 3.45 VOLTS
CLRDIST PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 11 (6.84) 11 (6.84) 11.5 (7.15) 13 (8.08) KM (MILES)
DTCCNT PID 0 0 0 0 NUMERIC VALUE
ECT ECT Sensor 96 (204.8) 88 (190.4) 86 (186.8) 88 (190.4) DEG C (DEG F)
EQ_RAT11 PID 0 1.02 0.99 0.99 RATIO
EQ_RAT21 PID 0 1.02 0.97 1.00 RATIO
ETC_ACT PID 7.99 4.80 7.85 5.23 DEG
ETC_TRIM PID -0.44 -0.44 -0.44 -0.44 DEG
FANSS FS Sensor 0 250 350 475 RPM
FLI Fuel Level Sensor 35 (H) 35 (H) 40 (H) 35 (H) %
FPM PID 39 40 40 40 %
FTP_V FTP Sensor 2.62 2.19 2.09 2.18 VOLTS
HTRCM11 HO2S11 Sensor 0.00 0.00 0.00 0.00 mA
HTRCM12 HO2S12 Sensor 0.00 0.00 0.00 0.00 mA
HTRCM21 HO2S21 Sensor 0.00 0.00 0.00 0.00 mA
HTRCM22 HO2S22 Sensor 0.00 0.00 0.00 0.00 mA
IAT IAT Sensor 39 (102.2) 34 (93.2) 27 (80.6) 24 (75.2) DEG C (DEG F)
IAT1 IAT Sensor 39 (102.2) 35 (95) 28 (82.4) 24 (75.2) DEG C (DEG F)
IAT1_V IAT Sensor 2.10 2.31 2.61 2.77 VOLTS
INJPWR_M PID 12.67 14.21 14.16 14.18 VOLTS
INJ1-8_F PID NO NO NO NO YES/NO
KNOCK_1 KS11 Sensor 999 41 78 75 COUNT
KNOCK_2 KS12 Sensor 999 43 68 53 COUNT
KNOCK_3 KS21 Sensor 999 26 55 36 COUNT
KNOCK_4 KS22 Sensor 999 22 51 36 COUNT
LOAD_ABSL PID 0.00 (I) 21 17 20 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 3.29 13.70 15.29 52.48 g/s
MAF_HZ MAF Sensor 5.00 2.98 2.90 2.06 kHz
MIL_DIS PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
MISFIRE PID FALSE FALSE FALSE FALSE TRUE/FALSE
MP_LRN PID FALSE FALSE FALSE FALSE TRUE/FALSE
NUM_MISFIRE PID 0 0 3 3 COUNT
O2S11_CUR HO2S11 Sensor 0 (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 1.05 1.04 1.07 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 122.10 122.10 122.10 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 1.04 1.04 1.05 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 125.30 125.30 125.30 Kohm
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OCTADJ_R_LRND PID 0 0 0 0 %
OSS_RAW OSS Sensor 0 0 1113 2006 RPM
PTO PID OFF OFF OFF OFF ON/OFF
PTOIR_V PID 0 0 0 0 VOLTS
PTOLOAD PID INACTIVE INACTIVE INACTIVE INACTIVE ACTIVE/INACTIVE
RO2FT1 PID 0 0.02 -0.01 0 %
RO2FT2 PID 0 0.02 -0.02 0 %
RPM CKP Sensor 0 799 1678 1270 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1_LRN_TRIM ETBTPS 6.13 6.13 6.13 6.13 DEG
TP1_PER ETBTPS 14 12 14 43 %
TP_REL PID 7 5 7 37 VOLTS
VCTSYS PID DISABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
VCT_EXH_ACT1 PID 0 0.13 33.75 29.13 DEG
VCT_EXH_ACT2 PID 0 0 0 0 DEG
VCT_EXH_DIF1 PID 0 -0.13 -0.56 -20.75 DEG
VCT_EXH_DIF2 PID 0 0 0 0 DEG
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AEIS_ACTION PID 0 0 0 0 NUMERIC VALUE
AEIS_POSS PID 0 0 0 0 NUMERIC VALUE
BOOSTP_EVAL PID YES YES NO NO YES/NO
CYL1-6_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
DIST_AEIS PID 0 (0) 0 (0) 0 (0) 0 (0) KM (MILES)
ETC [TAC_PCT] PID 9 5 9 8 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 56 97 43 %
EVAPCV CANV Valve 0 0 0 0 %/ON-OFF
EVAPPCT PID 0 56 97 56 %
EVAPSOAK PID NO NO NO NO YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
EVBV EVAP Vapor Blocking Valve 0 0 100 100 %/OPEN-CLOSED
FAN_DSD PID 0 0 0 0 %
FP Fuel Pump Control Module 75 31 31 31 %/ON/OFF
FUELSYS_CL PID NO YES YES YES YES/NO
FUELSYS_OL PID NO NO NO NO YES/NO
FUEL_RDY PID NO NO NO NO YES/NO
HFC PID OFF OFF OFF OFF ON/OFF
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
LFC PID OFF OFF OFF OFF ON/OFF
MFC PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20 27 28 24 %
O2S21_HTR HO2S21 Sensor 20 24 23 18 %
O2_DS_DISBL PID YES NO NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
PTOIL PTO Lamp INACTIVE INACTIVE INACTIVE INACTIVE ACTIVE/INACTIVE
SPARKADV PID 7 17 20 24 DEG
VCT_EXH_DC1 VCT12 Solenoid 0 0 44 31 %
VCT_EXH_DC2 VCT22 Solenoid 0 0 0 0 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS