Home >> Ford >> 2023 >> Transit Connect XL, Van Cargo >> Repair and Diagnosis (Single Page) >> Body & Frame >> Windows >> Glass, Frames And Mechanisms >> Description And Operation >> Glass, Frames and Mechanisms - Vehicles With: One-Touch Open and Close Front Windows - System Operation and Component Description >> System Operation >> Front Power Window Operation
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Front Power Window Operation

NOTE: If the vehicle battery is disconnected, the one-touch up and one-touch down feature (and obstacle detection) is disabled prior to initialization.

Refer to: Power Door Window Initialization 

The power windows operate when the delayed accessory power feature is active. Both front windows are equipped with obstacle detection and one-touch up and one-touch down functionality. If an obstacle has been detected in the window opening as the window glass is moving upward, the window motor automatically reverses direction and moves the glass downward.

LH Front Window Operation 

The master window control switch communicates to the DDM through a private LIN. When commanded by the master window control switch, the DDM supplies power and ground to operate the LH front window in the desired direction. The DDM monitors the window glass position through feedback from 2 Hall-effect sensors (integral to the power window motor). If there is an issue with the Hall-effect sensor circuit(s), the DDM only moves the window in 500 ms intervals (the window control switch must be released and activated again to move the window).

RH Front Window Operation 

The master window control switch communicates to the DDM through a private LIN. The DDM communicates to the PDM through the MS-CAN. When commanded by the master window control switch or the RH window control switch, the PDM supplies power and ground to operate the RH front window in the desired direction. The PDM monitors window glass position through feedback from 2 Hall-effect sensors (integral to the power window motor). If there is an issue with the Hall-effect sensor circuit(s), the PDM only moves the window in 500 ms intervals (the window control switch must be released and activated again to move the window).