Home >> Ford >> 2024 >> Bronco Big Bend, 2D Utility, Part Time T/Case Control, Automatic Trans >> Repair and Diagnosis (Single Page) >> Engine Performance >> Engine Control Systems >> Electronic Engine Controls - 2.7L ECOBOOST (238KW 324PS) -- Bronco >> Specifications >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

An attempt is made to provide as much information as possible. Some vehicles may not display all input and output signals.

The Typical Diagnostic Reference Value Charts do not display fault parameter identifications (PIDs). These are PIDs which indicate a hard fault with the circuit. They display a value of FAULT or NO FAULT and are PIDs ending with the letter F.

Reference values may vary 20% depending on operating conditions, altitude, and other factors. The RPM values are axle and tire dependent.

Values are taken at an altitude of approximately 189 meters (620 ft) above sea level with the engine at normal operating temperature and accessories off.

For detailed transmission diagnostics, refer to the appropriate Service Articles. Transmission signals may be referred to in either alpha or numeric form. For example, 1=A, 2=B, 3=C.

PID Units Measured/PID Component/PID Only Measured/PID Values
KOEO Hot Idle 48KM/H (30 MPH) 89 KM/H (55 MPH)
PCM AAT (Deg C) DEG C (DEG F) AAT Sensor 14 (57.2) 14 (57.2) 14 (57.2) 14 (57.2)
PCM AAT_V (V) VOLTS AAT Sensor 2.80 2.80 2.90 2.97
PCM APP (%) % APP Sensor 0 0 7 9
PCM APP1 (V) VOLTS APP Sensor 0.80 0.80 1.04 1.11
PCM APP1_[APP_D] (%) % APP Sensor 16 16 21 22
PCM APP2 (V) VOLTS APP Sensor 0.40 0.41 0.52 0.56
PCM APP2_[APP_E] (%) % APP Sensor 8 8 8 8
PCM APP_MAXDIFF (Deg) DEG PID 0 0 0 0
PCM BARO (kPa) kPa (PSI) PID 98 (14.21) 98 (14.21) 98 (14.21) 98 (14.21)
PCM BARO_V (V) VOLTS PID 3.84 3.84 3.84 3.84
PCM BATT_V_INF (V) VOLTS PID 12.65 14.71 14.69 14.69
PCM BRKOVRD_POSS NUMERIC VALUE PID 63 63 63 63
PCM BRKOVR_ACTION NUMERIC VALUE PID 0 0 0 0
PCM CAM_SYNC YES/NO PID NO NO NO NO
PCM CATTEMP11 (Deg C) DEG C (DEG F) CAT11 Sensor 418 (784.4) 421 (789.8) 535 (995) 804 (1, 486.4)
PCM CATTEMP21 (Deg C) DEG C (DEG F) CAT21 Sensor 418 (784.4) 421 (789.8) 536 (996.8) 803 (1, 477.4)
PCM CHT (Deg C) DEG C (DEG F) CHT Sensor 101 (213.8) 100 (212) 99 (210.2) 100 (212)
PCM CHT2 (Deg C) DEG C (DEG F) CHT2 Sensor 105 (221) 104 (219.2) 106 (222.8) 114 (237.2)
PCM CHT2_V (V) VOLTS CHT2 Sensor 3.24 3.25 3.19 2.92
PCM CLRDIST (km) KM (MILES) PID 0 (0) 0 (0) 0 (0) 0 (0)
PCM DECHOKE YES/NO PID YES NO NO NO
PCM DIST_AEIS (km) KM (MILES) PID 148 (91.96) 148 (91.96) 148 (91.96) 148.5 (92.27)
PCM DIST_BRKOVRD (km) KM (MILES) PID 0.5 (0.31) 0.5 (0.31) 0.5 (0.31) 1 (0.62)
PCM DPFE_PRES (kPa) kPa (PSI) Differential Pressure Feedback EGR Sensor -0.01 (-0.00) -0.02 (-0.00) 0.01 (0.00) 0.94 (0.14)
PCM DPFE_V (V) VOLTS Differential Pressure Feedback EGR Sensor 2.00 2.00 2.01 2.15
PCM DTCCNT NUMERIC VALUE PID 0 0 0 0
PCM DTCCNT_OBD NUMERIC VALUE PID 0 0 0 0
PCM EBP (kPa) kPa (PSI) EBP Sensor 99.69 (14.46) 96.41 (13.98) 108.44 (15.73) 104 (15.08)
PCM EBP_V (V) VOLTS EBP Sensor 0.98 0.93 1.11 1.12
PCM ECT (Deg C) DEG C (DEG F) ECT Sensor 101 (213.8) 99 (210.2) 98 (208.4) 100 (212)
PCM ECT1_V (V) VOLTS ECT Sensor 0.43 0.43 0.45 0.43
PCM EGRT_B (Deg C) DEG C (DEG F) EGRT12 Sensor 64 (147.2) 64 (147.2) 64 (147.2) 76 (168.8)
PCM EGRT_B_V (V) VOLTS EGRT12 Sensor 1.18 1.18 3.84 0.85
PCM EGRVP (V) VOLTS EGR Valve 0.57 0.56 0.56 0.94
PCM EGRVPDES (%) % PID 0 0 0 9
PCM EGR_A_ACT (%) % EGR Valve 1 0 0 9
PCM EGR_A_CMD (%) % PID 1 0 0 9
PCM EQ_RAT11 RATIO PID 0.00 1.02 1.02 0.93
PCM EQ_RAT21 RATIO PID 0.00 1.01 1.01 0.91
PCM ETC_ACT (Deg) DEG PID 7.53 2.41 7.42 8.92
PCM ETC_TRIM (Deg) DEG PID 0.33 (E) 0.33 (E) 0.33 (E) 0.33 (E)
PCM ETC_[TAC_PCT] (%) % PID 9 3 9 11
PCM EVAP020C YES/NO PID NO NO NO NO
PCM EVAPCP (%) % EVAPCP Valve 0 36 28 46
PCM EVAPCV (%) % CANV Valve 0 0 0 0
PCM EVAPPCT (%) % PID 0 36 27 45
PCM EVAPSOAK YES/NO PID FALSE TRUE FALSE FALSE
PCM EVAPSTA STATUS PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING
PCM EVBV (% Duty Cycle) % EVAP Vapor Blocking Valve 0 0 0 0
PCM FANELC_CMD (% Duty Cycle) % PID 8 9 0 11
PCM FAN_DSD (%) % PID 0 0 0 0
PCM FLI (%) % Fuel Level Sensor 26 (B) 26 (B) 22 (B) 35 (B)
PCM FLP (kPa) kPa (PSI) Fuel Pressure Sensor 629 (91.23) 615 (89.19) 676 (98.05) 663 (96.16)
PCM FLP_DSD (kPa) kPa (PSI) Fuel Pressure Sensor 603 (87.46) 603 (87.46) 603 (87.46) 603 (87.46)
PCM FLP_V (V) VOLTS Fuel Pressure Sensor 2.62 2.56 2.81 2.76
PCM FP (%) % Fuel Pump Control Module 75 22 31 25
PCM FPM (%) % PID 40 40 40 40
PCM FRP (kPa) kPa (PSI) FRP Sensor 8, 310 (1, 205.26) 6, 820 (989.16) 1, 1270 (1, 634.58) 10, 750 (1, 559.16)
PCM FRP_DSD (kPa) kPa (PSI) PID 520 (75.42) 2, 060 (298.78) 2, 060 (298.78) 2, 060 (298.78)
PCM FRP_V (V) VOLTS FRP Sensor 1.36 1.16 1.76 1.70
PCM FRT_A_RAW (Deg C) DEG C (DEG F) FRPT Sensor 65 (149) 65 (149) 66 (150.8) 66 (150.8)
PCM FRT_V (V) VOLTS FRT Sensor 1.04 1.04 1.02 1.04
PCM FTP_V (V) VOLTS FTP Sensor 2.62 2.62 2.49 2.44
PCM FUELSYS_A_PCT_B1 (%) % PID 0 0 0 37
PCM FUELSYS_A_PCT_B2 (%) % PID 0 0 0 37
PCM FUELSYS_B_PCT_B1 (%) % PID 0 100 100 63
PCM FUELSYS_B_PCT_B2 (%) % PID 0 100 100 63
PCM FUELSYS_CL YES/NO PID NO YES YES YES
PCM FUELSYS_OL YES/NO PID NO NO NO NO
PCM F_VCV_CMD (%) % Fuel Injection Pump 0 0 0 0
PCM HTR11 ON/OFF HO2S11 Sensor OFF ON ON ON
PCM HTR12 ON/OFF HO2S12 Sensor OFF ON ON ON
PCM HTR21 ON/OFF HO2S21 Sensor OFF ON ON ON
PCM HTR22 ON/OFF HO2S22 Sensor OFF ON ON ON
PCM HTRCM11 (Amp) mA HO2S11 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM12 (Amp) mA HO2S12 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM21 (Amp) mA HO2S21 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM22 (Amp) mA HO2S22 Sensor 0.00 0.00 0.00 0.00
PCM IAT (Deg C) DEG C (DEG F) IAT Sensor 59 (138.2) 59 (138.2) 55 (131) 46 (114.8)
PCM IAT11 (Deg C) DEG C (DEG F) IAT Sensor 59 (138.2) 59 (138.2) 55 (131) 46 (114.8)
PCM IAT12 (Deg C) DEG C (DEG F) IAT2 Sensor 57 (134.6) 56 (138.2) 46 (114.8) 31 (87.8)
PCM IAT1_V (V) VOLTS IAT Sensor 1.09 1.11 1.21 1.52
PCM IAT2 (Deg C) DEG C (DEG F) IAT2 Sensor 57 (134.6) 55 (132.8) 46 (114.8) 31 (87.8)
PCM IAT2_V (V) VOLTS IAT2 Sensor 1.16 1.21 1.51 2.13
PCM INJPWR_M (V) VOLTS PID 12.44 14.49 14.40 14.38
PCM KNK_CNTR_CYL1 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL2 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL3 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL4 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL5 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL6 COUNT PID 0 0 0 0
PCM KNOCK_1 COUNT KS11 Sensor 999 42.00 112.0 162
PCM KNOCK_2 COUNT KS12 Sensor 999 35.00 71.0 120
PCM LOAD (%) % PID 0 (A) 34 58 35
PCM LOAD_ABSL (%) % PID 0 (A) 20 49 51
PCM LONGFT1 (%) % PID (A) -20 TO +20 -20 TO +20 -20 TO +20
PCM LONGFT2 (%) % PID (A) -20 TO +20 -20 TO +20 -20 TO +20
PCM MAP (kPa) kPa (PSI) MAP Sensor 97 (14.07) 42 (6.09) 97 (14.07) 78 (11.31)
PCM MAP_V (V) VOLTS MAP Sensor 1.49 0.64 1.47 1.23
PCM MIL_DIS (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 0.0 (0.0)
PCM MIL_OBD ON/OFF PID OFF OFF OFF OFF
PCM MISFIRE TRUE/FALSE PID FALSE FALSE TRUE FALSE
PCM MP_LRN TRUE/FALSE PID TRUE TRUE TRUE TRUE
PCM NUM_MISFIRE COUNT PID 0 0 0 0
PCM O2S11_CUR (mA) mA/uA HO2S11 Sensor (A) switching (C) switching (C) switching (C)
PCM O2S11_HTR (%) % HO2S11 Sensor 22 58 27 24.13
PCM O2S11_IMPED (V) VOLTS HO2S11 Sensor 5.00 0.98 1.05 1.05
PCM O2S11_READY TRUE/FALSE HO2S11 Sensor FALSE TRUE TRUE TRUE
PCM O2S11_TR (Ohm) Kohm HO2S11 Sensor 0.00 131.6 131.6 131.6
PCM O2S12 (V) VOLTS HO2S12 Sensor (A) switching (D) switching (D) switching (D)
PCM O2S21_CUR (mA) mA/uA HO2S21 Sensor (A) switching (C) switching (C) switching (C)
PCM O2S21_HTR (%) % HO2S21 Sensor 22 70 25 25
PCM O2S21_IMPED (V) VOLTS HO2S21 Sensor 5.00 1.03 1.06 1.05
PCM O2S21_READY TRUE/FALSE HO2S21 Sensor FALSE TRUE TRUE TRUE
PCM O2S21_TR (Ohm) Kohm HO2S21 Sensor 0.00 101.8 101.8 101.8
PCM O2S22 (V) VOLTS HO2S22 Sensor (A) switching (D) switching (D) switching (D)
PCM O2_DS_DISBL TRUE/FALSE PID TRUE FALSE FALSE FALSE
PCM PATSENABL ENABLED / DISABLED PID ENABLED ENABLED ENABLED ENABLED
PCM RO2FT1 (%) % PID 0.00 -0.01 0.02 0.00
PCM RO2FT2 (%) % PID 0.00 0.01 0.02 0.00
PCM RPM (Rpm) RPM CKP Sensor 0 827 1, 765 1, 772
PCM RPM_DSD (RPM) RPM PID 1, 144 820 580 580
PCM SHRTFT1 (%) % PID (A) -10 TO +10 -10 TO +10 -10 TO +10
PCM SHRTFT2 (%) % PID (A) -10 TO +10 -10 TO +10 -10 TO +10
PCM SPARKADV (Deg) DEG PID 1.50 7.50 17.0 5.0
PCM SYNC YES/NO PID NO YES YES YES
PCM TCBP (kPa) kPa (PSI) TCBP Sensor 98.2 (14.24) 98.4 (14.27) 112.1 (16.26) 126.5 (18.35)
PCM TCBP_V (V) VOLTS TCBP Sensor 1.41 1.41 1.59 1.78
PCM TP1_LRN_TRIM (Deg) DEG ETBTPS 10.25 10.25 10.25 10.25
PCM TP1_PER (%) % ETBTPS 18 13 23 31
PCM TP2_LRN_TRIM (Deg) DEG ETBTPS 0 0 0 0
PCM TURBO_BP1_STAT FAULT/NO FAULT TCBY Valve NO FAULT NO FAULT NO FAULT NO FAULT
PCM TURBO_BPASS (%) % TCBY Valve 0 0 0 0
PCM TURBO_WGATE (%) % Turbocharger Wastegate Control 0 0 0 0
PCM VCTSYS ENABLED / DISABLED PID DISABLED ENABLED ENABLED ENABLED
PCM VCT_EXH_ACT1 (Deg) DEG PID 0.00 0.06 14.00 9.81
PCM VCT_EXH_ACT2 (Deg) DEG PID 0.00 -0.06 14.50 9.81
PCM VCT_EXH_DC1 (%) % VCT12 Solenoid 0.00 0.00 43.00 40.00
PCM VCT_EXH_DC2 (%) % VCT22 Solenoid 0.00 0.00 42.00 41.00
PCM VCT_EXH_DIF1 (Deg) DEG PID 0.00 -0.06 1.25 0.13
PCM VCT_EXH_DIF2 (Deg) DEG PID 0.00 0.06 1.19 0.13
PCM VCT_INT_ACT1 (Deg) DEG PID 0.00 -0.38 -20.19 -29.00
PCM VCT_INT_ACT2 (Deg) DEG PID 0.00 -0.06 -20.19 -29.63
PCM VCT_INT_DC1 (%) % VCT11 Solenoid 0.00 0.00 38.00 40.00
PCM VCT_INT_DC2 (%) % VCT21 Solenoid 0.00 0.00 38.00 40.00
PCM VCT_INT_DIF1 (Deg) DEG PID 0.00 0.25 0.44 -0.06
PCM VCT_INT_DIF2 (Deg) DEG PID 0.00 0.06 1.06 0.06
PCM VPWR (V) VOLTS PID VBAT VBAT VBAT VBAT
PCM VREF (V) VOLTS PID 9.55 9.55 9.55 9.55
PCM VSS (Kph) km/h (MPH) PID 0 (0) 0 (0) 48 km/h (30 MPH) 89 km/h (55 MPH)
PCM WGATE_A_POS_PCT (% Open) % Turbocharger Wastegate Motor 1 33.06 0.36 64.93 9.93
PCM WGATE_A_V (V) VOLTS Wastegate Position Sensor 1 2.02 1.20 3.15 1.45
PCM WGATE_B_POS_PCT (% Open) % Turbocharger Wastegate Motor 2 33.11 0.31 57.12 10.14
PCM WGATE_B_V (V) VOLTS Wastegate Position Sensor 2 2.04 1.22 2.69 1.49