Diagnostic Trouble Code (DTC) Chart
Diagnostics in this article assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .
| DTC | Module | Description | Action |
|---|---|---|---|
| P2CFC:00 | BCMC | A/C Clutch Control Circuit: No Sub Type Information | GO to Pinpoint Test C |
| P2CFD:00 | BCMC | A/C Clutch Control Circuit Low: No Sub Type Information | GO to Pinpoint Test C |
| P2CFE:00 | BCMC | A/C Clutch Control Circuit High: No Sub Type Information | GO to Pinpoint Test C |
| B105A:12 | HVAC | Cabin Temperature Sensor Fan: Circuit Short To Battery | GO to Pinpoint Test E |
| B105A:14 | HVAC | Cabin Temperature Sensor Fan: Circuit Short To Ground Or Open | GO to Pinpoint Test E |
| B1081:07 | HVAC | Left Temperature Damper Motor: Mechanical Failures | GO to Pinpoint Test G |
| B1081:11 | HVAC | Left Temperature Damper Motor: Circuit Short To Ground | GO to Pinpoint Test G |
| B1081:12 | HVAC | Left Temperature Damper Motor: Circuit Short To Battery | GO to Pinpoint Test G |
| B1081:13 | HVAC | Left Temperature Damper Motor: Circuit Open | GO to Pinpoint Test G |
| B1083:07 | HVAC | Recirculation Damper Motor: Mechanical Failures | GO to Pinpoint Test H |
| B1083:11 | HVAC | Recirculation Damper Motor: Circuit Short To Ground | GO to Pinpoint Test H |
| B1083:12 | HVAC | Recirculation Damper Motor: Circuit Short To Battery | GO to Pinpoint Test H |
| B1083:13 | HVAC | Recirculation Damper Motor: Circuit Open | GO to Pinpoint Test H |
| B1086:07 | HVAC | Air Distribution Damper Motor: Mechanical Failures | GO to Pinpoint Test I |
| B1086:11 | HVAC | Air Distribution Damper Motor: Circuit Short To Ground | GO to Pinpoint Test I |
| B1086:12 | HVAC | Air Distribution Damper Motor: Circuit Short To Battery | GO to Pinpoint Test I |
| B1086:13 | HVAC | Air Distribution Damper Motor: Circuit Open | GO to Pinpoint Test I |
| B10AF:11 | HVAC | Blower Fan Relay: Circuit Short To Ground | GO to Pinpoint Test M |
| B10AF:12 | HVAC | Blower Fan Relay: Circuit Short To Battery | GO to Pinpoint Test M |
| B10AF:13 | HVAC | Blower Fan Relay: Circuit Open | GO to Pinpoint Test M |
| B10B5:11 | HVAC | Left Panel Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test U |
| B10B5:15 | HVAC | Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test U |
| B10B6:11 | HVAC | Left Floor Air Discharge Temperature: Circuit Short To Ground | GO to Pinpoint Test U |
| B10B6:15 | HVAC | Left Floor Air Discharge Temperature: Circuit Short To Battery Or Open | GO to Pinpoint Test U |
| B10B8:63 | HVAC | Push Buttons: Circuit/Component Protection Time-Out | GO to Pinpoint Test Y |
| B10B9:12 | HVAC | Blower Control: Circuit Short To Battery | GO to Pinpoint Test M |
| B10B9:14 | HVAC | Blower Control: Circuit Short To Ground Or Open | GO to Pinpoint Test M |
| B10B9:14 | HVAC | Blower Control: Circuit Short To Ground Or Open | GO to Pinpoint Test N |
| B11E5:11 | HVAC | Left HVAC Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test G |
| B11E5:15 | HVAC | Left HVAC Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test G |
| B11E7:11 | HVAC | Air Distribution Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test I |
| B11E7:15 | HVAC | Air Distribution Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test I |
| B11F0:11 | HVAC | Air Intake Damper Position Sensor: Circuit Short To Ground | GO to Pinpoint Test H |
| B11F0:15 | HVAC | Air Intake Damper Position Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test H |
| B12CA:11 | HVAC | Start/Stop 'Eco-Start' Status Indicator: Circuit Short To Ground | GO to Pinpoint Test X |
| B12CA:15 | HVAC | Start/Stop 'Eco-Start' Status Indicator: Circuit Short To Battery Or Open | GO to Pinpoint Test X |
| B1A61:11 | HVAC | Cabin Temperature Sensor: Circuit Short To Ground | GO to Pinpoint Test E |
| B1A61:15 | HVAC | Cabin Temperature Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test E |
| B1A69:12 | HVAC | Humidity Sensor: Circuit Short To Battery | GO to Pinpoint Test E |
| B1A69:14 | HVAC | Humidity Sensor: Circuit Short To Ground Or Open | GO to Pinpoint Test E |
| B1B71:11 | HVAC | Evaporator Temperature Sensor: Circuit Short To Ground | GO to Pinpoint Test F |
| B1B71:15 | HVAC | Evaporator Temperature Sensor: Circuit Short To Battery Or Open | GO to Pinpoint Test F |
| C1B14:11 | HVAC | Sensor Supply Voltage A: Circuit Short To Ground | GO to Pinpoint Test W |
| C1B14:12 | HVAC | Sensor Supply Voltage A: Circuit Short To Battery | GO to Pinpoint Test W |
| U0100:00 | HVAC | Lost Communication With ECM/PCM 'A': No Sub Type Information | GO to Pinpoint Test O |
| U0140:00 | HVAC | Lost Communication With Body Control Module: No Sub Type Information | GO to Pinpoint Test P |
| U0151:00 | HVAC | Lost Communication With Restraints Control Module: No Sub Type Information | GO to Pinpoint Test Q |
| U0155:00 | HVAC | Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information | GO to Pinpoint Test R |
| U0253:00 | HVAC | Lost Communication With Accessory Protocol Interface Module: No Sub Type Information | GO to Pinpoint Test S |
| U0401:00 | HVAC | Invalid Data Received from ECM/PCM A: No Sub Type Information | GO to Pinpoint Test AB |
| U0401:82 | HVAC | Invalid Data Received from ECM/PCM A: Alive/Sequence Counter Incorrect/Not Updated | GO to Pinpoint Test AB |
| U0422:68 | HVAC | Invalid Data Received From Body Control Module: Event Information | GO to Pinpoint Test AB |
| U0422:81 | HVAC | Invalid Data Received From Body Control Module: Invalid Serial Data Received | GO to Pinpoint Test AB |
| U0452:82 | HVAC | Invalid Data Received From Restraints Control Module: Alive/Sequence Counter Incorrect/Not Updated | GO to Pinpoint Test AB |
| U1000:00 | HVAC | Solid State Driver Protection Active -Driver Disabled: No Sub Type Information | GO to Pinpoint Test T |
| U2024:51 | HVAC | Control Module Cal-Config Data: Not Programmed | GO to Pinpoint Test AC |
| U2100:00 | HVAC | Initial Configuration Not Complete: No Sub Type Information | GO to Pinpoint Test AC |
| U3000:41 | HVAC | Control Module: General Checksum Failure | GO to Pinpoint Test AD |
| U3000:49 | HVAC | Control Module: Internal Electronic Failure | GO to Pinpoint Test AD |
| U3003:16 | HVAC | Battery Voltage: Circuit Voltage Below Threshold | GO to Pinpoint Test Z |
| U3003:17 | HVAC | Battery Voltage: Circuit Voltage Above Threshold | GO to Pinpoint Test AA |
| P0532:00 | PCM | A/C Refrigerant Pressure Sensor 'A' Circuit Low: No Sub Type Information | GO to Pinpoint Test A |
| P0533:00 | PCM | A/C Refrigerant Pressure Sensor 'A' Circuit High: No Sub Type Information | GO to Pinpoint Test A |
| P0645:00 | PCM | A/C Clutch Relay Control Circuit: No Sub Type Information | GO to Pinpoint Test B |
| P06A0:00 | PCM | Variable A/C Compressor Control Circuit: No Sub Type Information | GO to Pinpoint Test D |
| P1464:00 | PCM | A/C Demand Out Of Self Test Range: No Sub Type Information | GO to Pinpoint Test K |
| P193E:00 | PCM | A/C Clutch Request Signal: No Sub Type Information | GO to Pinpoint Test V |
| P2600:00 | PCM | Coolant Pump 'A' Control Circuit/Open: No Sub Type Information | GO to Pinpoint Test AE |
| P2601:00 | PCM | Coolant Pump 'A' Control Circuit Performance/Stuck Off: No Sub Type Information | GO to Pinpoint Test AE |
| P2602:00 | PCM | Coolant Pump 'A' Control Circuit Low: No Sub Type Information | GO to Pinpoint Test AE |
| P2603:00 | PCM | Coolant Pump 'A' Control Circuit High: No Sub Type Information | GO to Pinpoint Test AE |