Typical Diagnostic Reference Values

NOTE: Footnotes are referenced throughout the Typical Diagnostic Reference Value Charts. A letter in parentheses next to a value indicates supplemental information is available.

An attempt is made to provide as much information as possible. Some vehicles may not display all input and output signals.

The Typical Diagnostic Reference Value Charts do not display fault parameter identifications (PIDs). These are PIDs which indicate a hard fault with the circuit. They display a value of FAULT or NO FAULT and are PIDs ending with the letter F.

Reference values may vary 20% depending on operating conditions, altitude, and other factors. The RPM values are axle and tire dependent.

Values are taken at an altitude of approximately 189 meters (620 ft) above sea level with the engine at normal operating temperature and accessories off.

For detailed transmission diagnostics, refer the appropriate service information. Transmission signals may be referred to in either alpha or numeric form. For example, 1=A, 2=B, 3=C.

  1. Value is not useful under this condition.
  2. Value depends on fuel tank level. Typical operating range is 15% (empty) to 90% (full).
  3. Heated oxygen sensors (HO2S) should switch from rich to lean at least once every 3 seconds. HO2S voltage should toggle above and below 0.450 DCV and never be a negative value. Valid HO2S switching occurs only during closed loop fuel control operation.
  4. Downstream oxygen sensors stay close to a constant voltage when the catalyst monitor is off (positive value only). When the catalyst monitor is on, the HO2S switches from rich to lean above and below 0.450 DCV and should never be a negative value. For downstream oxygen sensors (12, 22) greater activity results when the catalyst monitor is active.
  5. The normal operation value is from -1.5 to 3.5 degrees.
PID Units Measured/PID Component/PID Only Measured/PID Values
KOEO Hot Idle 48KM/H (30 MPH) 89 KM/H (55 MPH)
PCMAAT (Deg C) DEG C (DEG F) AAT Sensor 1 (33.8) 1 (33.8) 1 (33.8) 1 (33.8)
PCMAAT_V (V) VOLTS AAT Sensor 3.78 3.78 3.85 3.88
PCMAC_REQUEST YES/NO PID NO NO NO NO
PCMAPP (%) % APP Sensor 0 0 10 14
PCMAPP1 (V) VOLTS APP Sensor 0.81 0.81 1.12 1.25
PCMAPP1_[APP_D] (%) % APP Sensor 16 16 22 25
PCMAPP2 (V) VOLTS APP Sensor 0.41 0.41 0.57 0.63
PCMAPP2_[APP_E] (%) % APP Sensor 8 8 11 13
PCMAPP_MAXDIFF (Deg) DEG PID 0.00 0.00 0.00 0.00
PCMBARO (kPa) kPa (PSI) PID 99 (14.36) 99 (14.36) 99 (14.36) 99 (14.36)
PCMBARO_V (V) VOLTS PID 3.87 3.87 3.87 3.86
PCMBATT_V_INF (V) VOLTS PID 12.65 14.96 14.96 14.96
PCMBOOSTP_EVAL YES/NO PID YES YES YES YES
PCMBRKOVRD_POSS NUMERIC VALUE PID 9 9 9 9
PCMBRKOVR_ACTION NUMERIC VALUE PID 0 0 0 0
PCMCAC_T (Deg C) DEG C (DEG F) CACT Sensor 0 (0) 0 (0) 0 (0) 0 (0)
PCMCAM_SYNC YES/NO PID NO YES NO NO
PCMCATTEMP11 (Deg C) DEG C (DEG F) CAT11 Sensor 536 (996.8) 548 (1, 018.4) 579 (1, 074.2) 673 (1, 243.4)
PCMCHT (Deg C) DEG C (DEG F) CHT Sensor 82 (179.6) 85 (185) 85 (185) 87 (188.6)
PCMCHT2 (Deg C) DEG C (DEG F) CHT2 Sensor 100 (212) 97 (206.6) 101 (213.8) 106 (222.8)
PCMCHT2_V (V) VOLTS CHT2 Sensor 3.41 3.50 3.36 3.19
PCMCLRDIST (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 2.0 (1.24)
PCMCYL1_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCMCYL2_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCMCYL3_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCMCYL4_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCMDECHOKE YES/NO PID YES NO NO NO
PCMDIST_AEIS (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 0.0 (0.0)
PCMDIST_BRKOVRD (km) KM (MILES) PID 9.5 (5.90) 9.5 (5.90) 10.0 (6.21) 11.5 (7.15)
PCMDPFE_PRES (kPa) kPa (PSI) Differential Pressure Feedback EGR Sensor -0.14 (-0.02) -0.39 (-0.06) -0.14 (-0.02) 3.88 (0.56)
PCMDPFE_V (V) VOLTS Differential Pressure Feedback EGR Sensor 1.49 1.48 1.49 1.61
PCMDTCCNT NUMERIC VALUE PID 0 0 0 0
PCMDTCCNT_OBD NUMERIC VALUE PID 0 0 0 0
PCMEBP (kPa) kPa (PSI) EBP Sensor 100.14 (14.52) 99.42 (14.42) 102.33 (14.84) 101.69 (14.75)
PCMEBP_V (V) VOLTS EBP Sensor 0.98 1.06 0.95 0.93
PCMECT (Deg C) DEG C (DEG F) ECT Sensor 71 (159.8) 70 (158) 79 (174.2) 86 (186.8)
PCMECT1_V (V) VOLTS ECT Sensor 0.98 1.00 0.78 0.64
PCMEGRT_B (Deg C) DEG C (DEG F) EGRT12 Sensor -19 (-2.2) -19 (-2.2) -13 (8.6) -8 (17.6)
PCMEGRT_B_V (V) VOLTS EGRT12 Sensor 0.91 0.92 0.44 0.28
PCMEGRVP (V) VOLTS EGR Valve 0.91 0.91 1.13 1.20
PCMEGRVPDES (%) % PID 0 0 49 49
PCMEGR_A_ACT (%) % EGR Valve 0 0 7 10
PCMEGR_A_CMD (%) % PID 0 0 7 10
PCMEQ_RAT11 RATIO PID 0.00 1.02 1.03 1.08
PCMETC_ACT (Deg) DEG PID 12.49 3.47 9.79 11.37
PCMETC_TRIM (Deg) DEG PID 0.14 (E) 0.15 (E) 0.16 (E) 0.16 (E)
PCMETC_[TAC_PCT] (%) % PID 9 4 11 13
PCMEVAP020C YES/NO PID NO NO NO NO
PCMEVAPCP (%) % EVAPCP Valve 0 6 50 13
PCMEVAPCV (%) % CANV Valve 0 0 0 0
PCMEVAPPCT (%) % PID 0 6 50 13
PCMEVAPSOAK YES/NO PID NO NO NO NO
PCMEVAPSTA STATUS PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING
PCMEVBV (% Duty Cycle) % EVAP Vapor Blocking Valve 0 0 100 100
PCMFAN_DSD (%) % PID 8 8 8 8
PCMFLI (%) % Fuel Level Sensor 44 (B) 45 (B) 46 (B) 44 (B)
PCMFLP (kPa) kPa (PSI) Fuel Pressure Sensor 612 (88.76) 547 (79.34) 546 (79.19) 548 (79.48)
PCMFLP_DSD (kPa) kPa (PSI) Fuel Pressure Sensor 546 (79.19) 546 (79.19) 546 (79.19) 546 (79.19)
PCMFLP_V (V) VOLTS Fuel Pressure Sensor 3.97 3.57 3.57 3.58
PCMFP (%) % Fuel Pump Control Module 75 26 26 26
PCMFPM (%) % PID 40 40 40 40
PCMFRP (kPa) MPa (PSI) FRP Sensor 7.11 (1, 031.22) 4.93 (715.01) 7.50 (1, 087.78) 7.88 (1, 142.90)
PCMFRP_DSD (kPa) MPa (PSI) PID 0.430 (62.37) 4.96 (719.39) 7.69 (1, 115.34) 7.90 (1, 145.80)
PCMFRP_V (V) VOLTS FRP Sensor 1.31 1.06 1.37 1.40
PCMFRT_A_RAW (Deg C) DEG C (DEG F) FRPT Sensor 16 (60.8) 16 (60.8) 16 (60.8) 16 (60.8)
PCMFRT_V (V) VOLTS FRT Sensor 0 0 0 0
PCMFTP_V (V) VOLTS FTP Sensor 2.63 2.47 2.39 2.45
PCMFUELSYS_CL YES/NO PID NO YES YES YES
PCMFUELSYS_OL YES/NO PID NO NO NO NO
PCMHFC ON/OFF PID OFF OFF OFF OFF
PCMHTR11 ON/OFF HO2S11 Sensor OFF ON ON ON
PCMHTR12 ON/OFF HO2S12 Sensor OFF ON ON ON
PCMHTR21 ON/OFF HO2S21 Sensor OFF OFF OFF OFF
PCMHTR22 ON/OFF HO2S22 Sensor OFF OFF OFF OFF
PCMHTRCM11 (Amp) mA HO2S11 Sensor 0.00 0.00 0.00 0.00
PCMHTRCM12 (Amp) mA HO2S12 Sensor 0.00 0.00 0.00 0.00
PCMIAT (Deg C) DEG C (DEG F) IAT Sensor 37 (98.6) 26 (78.8) 24 (75.2) 20 (68)
PCMIAT11 (Deg C) DEG C (DEG F) IAT Sensor 37 (98.6) 26 (78.8) 23 (73.4) 20 (68)
PCMIAT12 (Deg C) DEG C (DEG F) IAT2 Sensor 33 (91.4) 30 (86) 26 (78.8) 14 (57.2)
PCMIAT1_V (V) VOLTS IAT Sensor 1.89 2.39 2.50 2.68
PCMIAT2 (Deg C) DEG C (DEG F) IAT2 Sensor 33(91.4) 30 (86) 26 (78.8) 24 (75.2)
PCMIAT2_V (V) VOLTS IAT2 Sensor 2.06 2.17 2.39 2.45
PCMINJ1_F YES/NO PID NO NO NO NO
PCMINJ2_F YES/NO PID NO NO NO NO
PCMINJ3_F YES/NO PID NO NO NO NO
PCMINJ4_F YES/NO PID NO NO NO NO
PCMINJECTOR_OFF -----/DISABLE Injector 1-4 ----- ----- ----- -----
PCMKNK_CNTR_CYL1 COUNT PID 0 0 0 0
PCMKNK_CNTR_CYL2 COUNT PID 0 0 0 0
PCMKNK_CNTR_CYL3 COUNT PID 0 0 0 0
PCMKNK_CNTR_CYL4 COUNT PID 0 0 0 0
PCMKNOCK_1 COUNT KS11 Sensor 999 81 69 89
PCMKNOCK_2 COUNT KS12 Sensor 999 85 82 100
PCMLOAD (%) % PID 0.00 (A) 41 40 29
PCMLOAD_ABSL (%) % PID 0.00(A) 23 36 43
PCMLONGFT1 (%) % PID (A) -20 TO +20 -20 TO +20 -20 TO +20
PCMMAP (kPa) kPa (PSI) MAP Sensor 99.00 () 38.50 () 68.00 () 71.00 ()
PCMMAP_V (V) VOLTS MAP Sensor 1.52 0, 59 1.04 1.14
PCMMIL_DIS (km) KM (MILES) PID 0 (0) 0 (0) 0 (0) 0 (0)
PCMMIL_OBD ON/OFF PID OFF OFF OFF OFF
PCMMISFIRE TRUE/FALSE PID FALSE FALSE FALSE FALSE
PCMMP_LRN TRUE/FALSE PID TRUE TRUE TRUE TRUE
PCMNUM_MISFIRE COUNT PID 0 0 0 0
PCMO2S11_CUR (mA) mA/uA HO2S11 Sensor (A) switching (C) switching (C) switching (C)
PCMO2S11_HTR (%) % HO2S11 Sensor 20 24 25 24
PCMO2S11_IMPED (V) VOLTS HO2S11 Sensor 5.00 0.17 0.17 0.17
PCMO2S11_READY YES/NO HO2S11 Sensor NO YES YES YES
PCMO2S12 (V) VOLTS HO2S12 Sensor (A) switching (D) switching (D) switching (D)
PCMO2S21_READY TRUE/FALSE HO2S21 Sensor NO YES YES YES
PCMO2_DS_DISBL TRUE/FALSE PID TRUE FALSE FALSE FALSE
PCMOCTADJ_R_LRND % PID 0 0 0 0
PCMPATSENABL ENABLED / DISABLED PID ENABLED ENABLED ENABLED ENABLED
PCMRO2FT1 (%) % PID 0.00 0.00 -0.01 0.03
PCMRPM (Rpm) RPM CKP Sensor 0 751 1954 1839
PCMRPM_DSD (Rpm) RPM PID 750 750 750 750
PCMSHRTFT1 (%) % PID (I) -10 TO +10 -10 TO +10 -10 TO +10
PCMSPARKADV (Deg) DEG PID 10.00 9.00 19.00 13.5
PCMSYNC YES/NO PID NO YES YES YES
PCMTCBP (kPa) kPa (PSI) TCBP Sensor 96.7() 96.9() 97.8 () 113.6()
PCMTCBP_V (V) VOLTS TCBP Sensor 1.42 1.42 1.43 1.65
PCMTP1_LRN_TRIM (Deg) DEG ETBTPS 6.13 6.13 6.13 6.13
PCMTP1_PER (%) % ETBTPS 18 9 14 27
PCMTP2_LRN_TRIM (Deg) DEG ETBTPS 0.00 0.00 0.00 0.00
PCMTP_REL (%) VOLTS PID 12 3 7 20
PCMTURBO_BP1_STAT FAULT/NO FAULT TCBY Valve NO FAULT NO FAULT NO FAULT NO FAULT
PCMTURBO_BPASS (%) % TCBY Valve 0 0 0 0
PCMTURBO_WGATE (%) % Turbocharger Wastegate Control 0 0 0 0
PCMVCTSYS ENABLED / DISABLED PID DISABLED ENABLED ENABLED ENABLED
PCMVCT_EXH_ACT1 (Deg) DEG PID 0.00 -0.25 30.31 19.94
PCMVCT_EXH_DC1 (%) % VCT12 Solenoid 0 0 41 35
PCMVCT_EXH_DIF1 (Deg) DEG PID 0.00 0.25 3.75 0.00
PCMVCT_INT_ACT1 (Deg) DEG PID 0.00 0.25 -11.19 -34.38
PCMVCT_INT_DC1 (%) % VCT11 Solenoid 0 0 32 39
PCMVCT_INT_DIF1 (Deg) DEG PID 0.00 -0.25 3.44 -0.38
PCMVPWR (V) VOLTS PID VBAT VBAT VBAT VBAT
PCMVREF (V) VOLTS PID 5 5 5 5
PCMVSS (Kph) km/h (MPH) PID 0 (0) 0 (0) 48 km/h (30 MPH) 89 km/h (55 MPH)
PCMWGATE_A_POS_PCT (% Open) % Turbocharger Wastegate Motor 1 32.76 0.00 43.20 95.82
PCMWGATE_A_V (V) VOLTS Wastegate Position Sensor 1 2.45 1.58 2.70 4.09