Home >> Ford >> 2024 >> Mustang Mach-E GT >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - General Information >> Description And Operation >> Climate Control System - System Operation and Component Description >> Component Description >> Air Conditioning (A/C) Line Bundle
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Air Conditioning (A/C) Line Bundle

The evaporator inlet and outlet manifold incorporates the Internal Heat Exchanger (IHX) and is serviced as an assembly called the Air Conditioning (A/C) Line Bundle. The Internal Heat Exchanger (IHX) combines a section of the A/C suction and liquid refrigerant lines into one component. It uses the cold vapor from the evaporator to cool the hot liquid from the condenser before it enters the Thermostatic Expansion Valve (TXV). After the Thermostatic Expansion Valve (TXV), more liquid refrigerant is available for absorbing heat in the evaporator. The result is an increase in cooling and operating efficiency of the HVAC system.