DELCO-REMY Pivoted Plate: Overhaul: Disassembly
Remove rotor. Disconnect primary and condenser leads from between plastic retainer and breaker set spring. Remove contact points adjusting hold-down screw and remove contact points assembly. Remove primary lead and retainer. Remove condenser and bracket. Remove screws from vacuum advance diaphragm bracket, using slight downward pressure to disengage lever, remove vacuum advance unit. Remove breaker plate attaching screws and remove breaker plate.
NOTE:
do not disassemble breaker plate.