Bi-Metallic Vacuum Switching Valve (Prizm)
Remove bi-metallic vacuum switching valve from intake manifold. With sensing portion of valve in water at a temperature of 39°F (35°C), valve should not allow air to pass through ports. At a temperature of 58°F (50°C), valve should allow air to pass through ports.