Vacuum Switch C
- Disconnect vacuum hose No. 15 to vacuum switch C and connect hand vacuum pump to hose. Apply 12 in. Hg to switch. Check for continuity between Black/Yellow and Blue/Black wire terminals of control box 6P connector.
- Continuity should be present when more than 12 in. Hg is applied, and no continuity when vacuum is released.