October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Sensor Operating Range Charts
ATMOSPHERIC PRESSURE (PA) SENSOR VOLTAGE TEST
| BARO Pressure - In. Hg |
Volts |
| 0 |
2.8-3.0 |
| 5 |
2.3-2.5 |
| 10 |
1.8-2.0 |
| 15 |
1.3-1.5 |
| 20 |
.8-1.0 |
| 25 |
.3-.5 |
COOLANT TEMPERATURE (TW) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Resistance (Ohms) |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1,000-4,000 |
| 176 (80) |
200-400 |
INTAKE AIR TEMPERATURE (TA) SENSOR RESISTANCE TEST
| Temperature - °F (°C) |
Resistance (Ohms) |
| -4 (-20) |
15,000-18,000 |
| 68 (20) |
1,000-4,000 |
| 176 (80) |
200-400 |
MAP SENSOR VOLTAGE TEST
| Vacuum Applied - In. Hg. |
Volts |
| 0 |
2.8-3.0 |
| 5 |
2.3-2.5 |
| 10 |
1.8-2.0 |
| 15 |
1.3-1.5 |
| 20 |
.8-1.0 |
| 25 |
.3-.5 |
EGR LIFT SENSOR VOLTAGE TEST
| Position |
Volts (Approx.) |
| Accord & Prelude |
| Fully Closed |
1.2 |
| Fully Open |
4.0 |
| Civic & CRX |
| Fully Closed |
1.0 |
| Fully Open |
4.5 |
OXYGEN SENSOR VOLTAGE TEST
| Condition |
Volts |
| Lean |
Less Than 0.4 |