Remove brush holder from alternator. Using vernier caliper, measure brush length. See Fig 1. If brush length is not as specified, replace brushes. See BRUSH LENGTH SPECIFICATIONS table.
BRUSH LENGTH SPECIFICATIONS
| Application | In. (mm) |
|---|---|
| Standard | .41 (10.5) |
| Limit | .22 (5.6) |