Float Test
- Make sure the fuel tank is less than half full.
- Remove the fuel fill cap to relieve the fuel tank pressure, then reinstall the cap.
- Remove the fuel pipe cover. Disconnect the fuel tank vapor recirculation tube (A), and connect a vacuum pump/gauge, 0-30 in.Hg, to the tube.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Plug the line (B).
- Apply vacuum to the fuel tank vapor recirculation tube (A).