EVAP Leak Monitor
NOTE:
When negative battery cable is disconnected, all readiness test codes are cleared. If engine is stopped while performing steps 2- 5
, repeat test from step 1.
- Ensure fuel level is 60-90% of capacity, NOT full. Turn ignition off and allow vehicle to sit for more than 8 hours. Ensure ambient temperature is 20-95°F (-7-35°C). Connect scan tool to DLC.
- Start engine and drive vehicle for about 15 minutes. During drive, keep vehicle speed steady between 50-70 MPH, without moving accelerator pedal, for about 1 minute. Stop vehicle. Do not stop engine.
- Repeat step 2 two more times. Check for readiness code with scan tool. If readiness code is not set, go to next step.
- When ambient temperature is less than 32°F (0°C), hold engine speed at 3000 RPM under no load condition with transaxle in Park or Neutral until radiator cooling fan comes on.
- Remove fuel filler cap. Reinstall fuel filler cap.
- Drive vehicle for about 20 minutes on highway/freeway. During drive, keep vehicle speed steady between 50-70 MPH, without moving accelerator pedal, for about 1 minute. Stop vehicle. Do not stop engine.
- Repeat step 6 two more times. Check for readiness code with scan tool.