LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2005 >> Pilot EX >> Repair and Diagnosis >> Engine Performance >> System >> Fuel And Emissions Systems >> How to Set Readiness Codes >> Evaporative Emission (EVAP) Control System Monitor and Readiness Code >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Evaporative Emission (EVAP) Control System Monitor and Readiness Code: Procedure

  1. Connect the HDS to the vehicle's data link connector (DLC).
  2. Start the engine.
  3. Select EVAP TEST in the INSPECTION MENU with the HDS, then select the FUNCTION TEST in the EVAP TEST MENU.
    • If the result is normal, readiness is complete.
    • If the result is not normal, go to the next step.
  4. If the readiness code is still not set to complete, check for a temporary DTC. If there is no DTC, one or more of the enable criteria were probably not met; repeat the procedure.