LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2007 >> Fit Base, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 56 (Engine Control System (2TR-FE)) >> SFI System >> OBD II Monitor Specifications >> Typical Malfunction Thresholds
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Malfunction Thresholds

WARNING: This page is about a different car, the 2007 Toyota Tacoma. However, it is still accessible from the selected car via links, so may be relevant.
TYPICAL MALFUNCTION THRESHOLDS - DESCRIPTION CHART

One of following conditions met -
EVAP pressure just after reference pressure measurement start More than -1 kPa (-7.5 mmHg)
Reference pressure Less than -4.85 kPa (-36.4 mmHg)
Reference pressure -1.057 kPa (-7.9 mmHg) or more
Reference pressure Not saturated within 60 seconds
Difference between first and second reference pressure 0.7 kPa (5.3 mmHg) or more


P2419: Vent valve stuck closed 

TYPICAL MALFUNCTION THRESHOLDS - DESCRIPTION CHART

One of the following conditions set -
EVAP pressure just after reference pressure measurement start More than -1 kPa (-7.5 mmHg)
Reference pressure Less than -4.85 kPa (-36.4 mmHg)
Reference pressure -1.057 kPa (-7.9 mmHg) or more
Reference orifice leak criterion Not saturated within 60 seconds
Difference between first reference pressure and second reference pressure More than 0.7 kPa (5.25 mmHg)

P2420: Vent valve stuck open (vent) 

PRESSURE SPECIFICATIONS

EVAP pressure change after vent valve turned ON Less than 0.3 kPa (2.25 mmHg)