LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2008 >> S2000 Base >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel And Emissions Systems >> How to Set Readiness Codes >> Evaporative Emission (EVAP) Control System Monitor and Readiness Code >> Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Evaporative Emission (EVAP) Control System Monitor and Readiness Code: Procedure

  1. Connect the HDS to the vehicle's data link connector (DLC).
  2. Start the engine.
  3. Select EVAP TEST in the INSPECTION MENU with the HDS, then select the FUNCTION TEST in the EVAP TEST MENU.
    • If the result is are normal, readiness is complete.
    • If the result is are not normal, go to the next step.
  4. Check for a Temporary DTC. If there is no DTC, one or more of the enable criteria were probably not met; repeat the procedure.