AIR CONDITIONING SPECIFICATION

Item Measurement Qualification Standard or New Service Limit
Refrigerant Type   HFC-134a(R-134a)
Capacity of system   450-500 g (15.8-17.6 oz) -
Refrigerant oil Type   SP-10(P/N38897-P13-A01AH)
Capacity of components Condenser (Including receiver/dryer) 25mL(5/6 fl.oz)
Evaporator 35 mL (1 1/6 fl.oz)
Each line and hose 10 mL (1/3 fl.oz)
Receiver/Dryer 10 mL (1/3 fl.oz)
Compressor 80-90 mL (2 2/3-3 fL.oz)
Compressor Field coil resistance At 68 °F (20 °C) 3.15-3.45 Ω
Pulley-to-armature plate clearance   0.35-0.65 mm (0.014-0.026 in) -