DTC B1906: Immobilizer Unit Lost Communication With Gauge Control Module (A/T Message)
- Clear the DTCs with the HDS.
- Turn the ignition switch to LOCK (0) and then back to ON (II).
- Wait for at least 6 seconds.
- Check for DTCs with the HDS.
Is DTC B1906 indicated?
YES -Go to step 5.
NO -Intermittent failure, the system is OK at this time. Check for loose or poor connections between the gauge control module and the immobilizer-keyless control unit.
- From the BODY ELECTRICAL SYSTEM SELECT menu, select B-CAN CONTROL UNITS INFORMATION, and then select CHECK CONNECTED CONTROL UNITS.
Is the gauge control module detected?
YES - Go to 8.
NO - Go to 6.
- Measure the voltage between body ground and gauge control module 32P connector terminals No. 1 and No. 17 individually.Fig 1: Measuring Voltage Between Body Ground And Gauge Control Module 32P Connector Terminals No. 1 And No. 17
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there battery voltage?
YES -Go to step 7.
NO -Check the No. B1 (15 A) and the No. B22 (7.5 A) fuses in the under-dash fuse/relay box. If the fuse is blown, replace the fuse and recheck the DTCs. If the fuses are OK, repair an open in the wire between the under-dash fuse/relay box and the gauge control module.
- Measure the voltage between body ground and gauge control module 32P connector terminals No. 4 and No. 32 individually.Fig 2: Measuring Voltage Between Body Ground And Gauge Control Module 32P Connector Terminals No. 4 And No. 32
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there less than 0.2 V?
YES -Go to step 8.
NO -Repair an open or high resistance in the wire or poor ground(G501).
- Turn the ignition switch to LOCK (0).
- Disconnect under-dash fuse/relay box connector Y (16P).
- Check for continuity between immobilizer-keyless control unit up connector terminal No. 4 and gauge control module 32P connector terminal No. 31.Fig 3: Checking Continuity Between Immobilizer-Keyless Control Unit up Connector Terminal No. 4 And Gauge Control Module 32P Connector Terminal No. 31
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Replace the gauge control module (see GAUGE CONTROL MODULE REPLACEMENT ).
NO -Repair an open or high resistance in the wire.