LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2015 >> Pilot EX, FWD >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control >> System Description >> Climate Control Unit Inputs and Outputs
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Climate Control Unit Inputs and Outputs

Fig 1: Identifying Climate Control Unit Connector A (36P) Terminals
G08090366Courtesy of AMERICAN HONDA MOTOR CO., INC.
CONNECTOR A

Cavity Wire color Terminal name Description Signal
1 WHT B-CAN H B-CAN communication line --
2 GRY S5V Power source for humidity sensor, A/C pressure sensor, and air mix control motor (driver's, passenger's and rear) With ignition switch ON (II): about 5 V
3 YEL Hum Inputs humidity sensor signal --
4 LT BLU Tr Inputs in-car temperature sensor signal --
5 RED S-COM Ground exclusive for sensor Less than 0.5 V at all times
6 BLU BLW-V (Fr) Feed back signal of power transistor drain voltage With ignition switch ON (II): battery voltage (depending on blower motor speed)
7 RED BLW-G (Fr) Outputs power transistor gate voltage Fan switch to MAX: about 10 V Fan switch to MIN: about 2 V
8 LT GRIM/BLK M-HOT(Ps) Drives passenger's air mix control motor on the HOT side Drive on HOT side: battery voltage
9 PUR M-COOL (Ps) Drives passenger's air mix control motor on the COOL side Drive on COOL side: battery voltage
10 YEL FRS The recirculation control motor on the FRESH side Drive on FRESH side: battery voltage
11 BLU/ORN REC The recirculation control motor on the RECIRCULATE side Drive on FRESH side: battery voltage
12 PNK M-HOT (Rr) Rear air mix control motor on the HOT side Drive on HOT side: battery voltage
13 GRY M-COOL (Rr) Rear air mix control motor on the COOL side Drive on COOL side: battery voltage
14 ORN M-COOL (Dr) Drives driver's air mix control motor on the COOL side Drive on COOL side: battery voltage
15 RED/BLK M-HOT(Dr) Drives driver's air mix control motor on the HOT side Drive on HOT side: battery voltage
16 GRN M-DEF (Fr) Front mode control motor on the DEF side Drive on DEF side: battery voltage
17 GRN/WHT M-VENT(Fr) Front mode control motor on the VENT side Drive on VENT side: battery voltage
18 YEL IG2 IG2 power supply With ignition switch ON (II): battery voltage
19 LT GRN B-CAN L B-CAN communication line --
21 YEL AMD-P (Dr) Outputs driver's air mix control motor potentiometer signal Drive on COOL side: about 1.5 V Drive on HOT side: about 4.5 V
22 ORN AMD-P (Ps) Outputs passenger's air mix control motor potentiometer signal Drive on COOL side: about 1.5 V Drive on HOT side: about 4.5 V
23 LT GRN Pd A/C pressure sensor signal With A/C switch ON: about 1.4-4.8 V (depending on A/C pressure)
24 PUR Tsun Inputs sunlight sensor signal --
25 PNK Tarn Inputs outside air temperature sensor signal --
26 BRN Teva (Fr) Inputs front evaporator temperature sensor signal --
27 WHT/BLU Teva (Rr) Inputs rear evaporator temperature sensor signal --
29 BLU MODE 4 Inputs front mode control motor signal 4 --
30 BLU/BLK MODE 3 Inputs front mode control motor signal 3 --
31 LT BLU MODE 2 Inputs front mode control motor signal 2 --
32 PNK MODE1 Inputs front mode control motor signal 1 --
33 GRY MODE 3 Inputs recirculation control motor signal 3 --
34 BLK MODE 2 Inputs recirculation control motor signal 2 --
35 WHT MODE1 Inputs recirculation control motor signal 1 --
36 BLK GND Climate control unit ground (G403) Less than 0.2 V at all times


Fig 1: Identifying Climate Control Unit Connector B (12P) Terminals
G08090367Courtesy of AMERICAN HONDA MOTOR CO., INC.
CONNECTOR B

Cavity Wire color Terminal name Description Signal
1 GRN BUS DATA Front-Rear communication --
2 BLU DISP-SI Outputs Audio-HVAC display unit A/C communication data --
3 PUR DISP-CLK Audio-HVAC display unit A/C communication data clock --
4 BLU BLW-G (Rr) Outputs rear power transistor gate voltage Fan switch to MAX: about 10 V Fan switch to MIN: about 2 V
5 RED/GRN BLW-V (Rr) Feed back signal of rear power transistor drain voltage With ignition switch ON (II): battery voltage (depending on blower motor speed)
6 LT BLU ILL+ Power source for illumination With lighting switch ON: battery voltage
7 PUR AMD-P (Rr) Outputs rear air mix control motor potentiometer signal Drive on COOL side: about 0.5 V Drive on HOT side: about 4.5 V
9 BRN/WHT M-HEAT (Rr) Rear mode control motor on the HEAT side Drive on HEAT side: battery voltage
10 BLK M-VENT (Rr) Rear mode control motor on the VENT side Drive on VENT side: battery voltage
11 LT GRN Rr DEF Rly Signal for rear window defogger relay --
12 YEL ILL- Ground for illumination --