Terminal number Terminal name Description Signal
1 +B P/W AS Power source for control unit About battery voltage at all times
2 P/W AS MTR DOWN Drives front passenger's power window motor With front passenger's power window DOWN operation: about battery voltage.
If none of above conditions are met: less than 0.2 V
3 GND Ground for front passenger's power window switch Less than 0.2 V at all times
4 P/W AS MTR UP Drives front passenger's power window motor With front passenger's power window UP operation: about battery voltage
If none of above conditions are met: less than 0.2 V
5 Not used --- ---
6 Not used --- ---
7 Not used --- ---
8 Not used --- ---
9 Not used --- ---
10 Not used --- ---
11 Not used --- ---
12 Not used --- ---
13 Not used --- ---
14 Not used --- ---
15 Not used --- ---
16 Not used --- ---
17 AS MIRROR COM Outputs AS MIRROR COM signal ---
18 AS MIRROR UD Outputs AS MIRROR UD signal ---
19 AS MIRROR LR Outputs AS MIRROR LR signal ---
20 Not used --- ---
21 Not used --- ---
22 Not used --- ---
23 * H/MIRROR AS Outputs H/MIRROR AS signal With mirror defogger ON: about battery voltage
24 Not used --- ---
25 P/W AS MTR SGND Ground for front passenger's power window motor pulser Less than 0.2 V at all times
26 Not used --- ---
27 Not used --- ---
28 Not used --- ---
29 Not used --- ---
30 Not used --- ---

*: With mirror defogger

Terminal number Terminal name Description Signal
31 P/W AS MTR VCC Outputs P/W AS MTR VCC signal With front passenger's power window control unit is wakeup mode: about battery voltage
With front passenger's power window control unit is sleep mode: less than 0.2 V
32 Not used --- ---
33 Not used --- ---
34 LIN (P/W) Communication line ---
35 P/W AS MTR PLSA P/W AS MTR PLSA signal ---
36 AS SILCON UNLOCK Detects AS SILCON UNLOCK signal With front passenger's door lock knob switch LOCK: about battery voltage
With front passenger's door lock knob switch UNLOCK: less than 0.2 V
37 P/W AS MTR PLSB P/W AS MTR PLSB signal ---