Malfunction Threshold
Either of the condition continues for at least 5 seconds:
- The front secondary HO2S (bank 2, sensor 2) output voltage (voltage difference between SO2B2 and SO2SGB2 terminals) is 1.42*1 (3.28)*2 V or more.
- The SO2SGB2 terminal voltage is 3.65*1 (3.47)*2 V or more.
*1 : 6-Speed A/T
*2 : 9-Speed A/T
[ ]: HDS Parameter