Malfunction Threshold

A malfunction is detected if the following conditions are present after the engine has stopped and the vehicle condition has been turned to the OFF (LOCK) mode for at least 6 hours before restarting the engine:

Temperature difference between each sensor values Malfunction judgment
ECT1* - ECT2** IAT*** - ECT2** ECT sensor 1 IAT sensor ECT sensor 2
Higher than
57 °F (32 °C)
Higher than 57 °F (32 °C) Normal Normal Failure
From -43 °F (-24 °C) to 57 °F (32 °C) Failure Normal Normal
Lower than -43 °F (-24 °C) Failure Failure Normal
From
-43 °F (-24 °C) to 57 °F (32 °C)
Higher than 57 °F (32 °C) Normal Failure Normal
From -43 °F (-24 °C) to 57 °F (32 °C) Normal Normal Normal
From -44 °F (-25 °C) to -115 °F (-64 °C) Normal Failure Normal
Suspended****
Lower than -115 °F (-64 °C) Normal Failure Normal
Lower than
-43 °F (-24 °C)
Higher than 57 °F (32 °C) Failure Failure Normal
From -43 °F (-24 °C) to 57 °F (32 °C) Failure Normal Normal
Lower than -43 °F (-24 °C) Normal Normal Failure

*: [ECT SENSOR 1]

**: [ECT SENSOR 2]

***: [IAT SENSOR (1)]

****: Malfunction judgment is suspended because the cooled air introduced after engine start lowers the intake air temperature; the ambient temperature condition does not stay equal.