DTC P172A

DTC P172A:  KEY-Release Wake-up Output Circuit Malfunction

General Description 

GHH416846Courtesy of HONDA, U.S.A., INC.
GHH416847Courtesy of HONDA, U.S.A., INC.

At the condition the vehicle is in OFF (LOCK) mode, the SBW shifter control module in the SBW shifter assembly turns the SRKS output to ON (12 V) when the key release switch is pressed once. The SBW shifter control module monitors the return signal of the SRKS output, and when the return signal and SRKS output does not match for a specified duration, the powertrain control module (PCM) receives malfunction from the SBW shifter control module, and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Continuous
Sequence None
Duration 2 seconds or more
DTC Type One drive cycle, MIL off, Shift position indicator off

Enable Conditions 

Condition  
Vehicle ON mode

Malfunction Threshold 

The return signal is abnormal for at least 2 seconds when the SRKS outputs OFF.

Possible Cause 

NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
  • SBW shifter control module SRKS line short to power
  • SBW shifter assembly internal failure
  • Body control module internal failure

Confirmation Procedure 

Operating Condition 

Turn the vehicle to the ON mode, and wait for at least 10 seconds.

With the HDS 

None.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory. The MIL does not come on and the shift position indicator does not blink.

Conditions for clearing the DTC 

The Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.