LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Honda >> 2019 >> Insight EX >> Repair and Diagnosis >> Electrical >> Charging Systems >> Battery Management System - Diagnostics (1 Of 2) >> DTC Advanced Diagnostics >> DTC P0562 (Battery Condition Monitor Module)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P0562 (Battery Condition Monitor Module)

DTC P0562:  Battery Condition Monitor Module System Voltage Low

General Description 

GHH382794Courtesy of HONDA, U.S.A., INC.

The battery condition monitor module monitors the voltage of back-up power supply. When the back-up power supply voltage is a specified voltage for a set time, a malfunction is detected and a DTC.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Continuous
Sequence None
Duration 2.0 seconds or more
DTC Type One drive cycle, MIL on, POWER SYSTEM indicator on

Enable Conditions 

Condition Minimum Maximum
12 volt battery voltage 7.7 V -

Malfunction Threshold 

The back-up power supply voltage is 2.0 V or less for at least 2.0 seconds.

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the battery condition monitor module memory.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command.