Confirmation Procedure
Operating Condition
- After the vehicle has been left for an appropriate amount of time as specified, with the engine coolant temperature [ECT SENSOR 1] and intake air temperature [IAT SENSOR (1)] within the specified range, start the engine.
- Drive the vehicle immediately at a speed between 25 - 75 mph (40 - 120 km/h) for at least 23 minutes.
- After stopping the vehicle, turn the vehicle to the OFF (LOCK) mode and leave the vehicle in this condition for at least 37 minutes (EONV executes).
- Drive the vehicle in this manner only if the traffic regulations and ambient conditions allow.
With the HDS
Do the EVAP FUNCTION TEST in the Function Test Menu with the HDS.