DTC P24BF

DTC P24BF:  Canister Change Over Valve Control Circuit High Voltage

General Description 

GHH416914Courtesy of HONDA, U.S.A., INC.

The EVAP leak check module change valve is installed in the EVAP leak check module and used to seal up the EVAP passage when performing the EVAP leak check. The EVAP leak check module change valve is normally open (open to the atmosphere) and only closed (sealed) when performing the EVAP leak check. The powertrain control module (PCM) detects a malfunction and stores a DTC when the close signal is returned continuously for the prescribed time or more though close signal is not output to the EVAP leak check module change valve.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Once per driving cycle
Sequence None
Duration 2.0 seconds or more
DTC Type Two drive cycles, MIL on

Enable Conditions 

Condition Minimum Maximum
Battery voltage [Battery] 10.0 V -

[ ]: HDS Parameter

Malfunction Threshold 

When open signal is returned continuously for 2.0 seconds or more though close signal is output to the EVAP leak check module change valve.

Possible Cause 

NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
  • EVAP LEAK CHECK MODULE VSV line short to power
  • EVAP leak check module change valve internal circuit leak
  • PCM internal circuit failure

Confirmation Procedure 

Operating Condition 

Turn the vehicle to the ON mode.

With the HDS 

Select the EVAP TEST in the INSPECTION MENU, then select the FUNCTION TEST with the HDS.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected during the first drive cycle, a Pending DTC is stored in the PCM memory. If the malfunction returns in the next (second) drive cycle, the MIL comes on and a Confirmed DTC and the freeze data are stored.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.