Power Seat Control Unit Connector For Inputs And Outputs

Connector Index
POWER SEAT CONTROL UNIT CONNECTOR A (20P)
POWER SEAT CONTROL UNIT CONNECTOR B (12P)
GHH310363Courtesy of HONDA, U.S.A., INC.
Terminal number Terminal name Description Signal
1 ATP-P Detects ATP-P signal With out of P position: about battery voltage
With P position: less than 0.2 V
2 Not used - - - - - -
3 Not used - - - - - -
4 Not used - - - - - -
5 Not used - - - - - -
6 SVCC Power source for power seat sensor With power seat control unit in wakeup mode: about 5 V
7 FHSE Detects FHSE signal About 0.5 - 4.5 V (depending on front up-down position)
8 SLSE Detects SLSE signal About 0.5 - 4.5 V (depending on slide position)
9 RHSE Detects RHSE signal About 0.5 - 4.5 V (depending on rear up-down position)
10 RESE Detects RESE signal About 0.5 - 4.5 V (depending on recline position)
11 +B BACKUP Power source for power seat control unit About battery voltage at all times
12 Not used - - - - - -
13 IG1 METER IG1 power source With vehicle in ON or START mode: about battery voltage
14 Not used - - - - - -
15 Not used - - - - - -
16 B-CAN_H Communication line - - -
17 B-CAN_L Communication line - - -
18 UART (DPMS) Communication line - - -
19 SEG Ground for power seat sensor Less than 0.2 V at all times
20 GND Ground for power seat control unit Less than 0.2 V at all times
GHH310364Courtesy of HONDA, U.S.A., INC.
Terminal number Terminal name Description Signal
1 SLIDE RR Drives slide motor With slide motor operation (rear side): about battery voltage
2 GND Ground for power seat control unit Less than 0.2 V at all times
3 SLIDE FR Drives slide motor With slide motor operation (front side): about battery voltage
4 RR HT DN Drives rear up-down motor With rear up-down motor operation (down): about battery voltage
5 GND Ground for power seat control unit Less than 0.2 V at all times
6 +B DR P/SEAT(SLI) Detects +B DR P/SEAT(SLI) signal About battery voltage at all times
7 FR HT DN Drives front up-down motor With front up-down motor operation (down): about battery voltage
8 REC FR Drives recline motor With recline motor operation (front side): about battery voltage
9 RR HT UP Drives rear up-down motor With rear up-down motor operation (up): about battery voltage
10 FR HT UP Drives front up-down motor With front up-down motor operation (up): about battery voltage
11 REC RR Drives recline motor With recline motor operation (rear side): about battery voltage
12 +B DR P/SEAT(REC) Detects +B DR P/SEAT(REC) signal About battery voltage at all times