Battery Condition Monitor Module Connector for Inputs and Outputs
Battery Condition Monitor Module Connector for Inputs and Outputs
| Connector Index |
| Battery Condition Monitor Module Connector A (28P) |
| Battery Condition Monitor Module Connector B (28P) |
| Battery Condition Monitor Module Connector C (28P) |
| Battery Condition Monitor Module Connector D (16P) |
| Battery Condition Monitor Module Connector E (32P) |
| Battery Condition Monitor Module Connector F (12P) |
Battery Condition Monitor Module Connector A (28P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
Not used |
|
| 2 |
Not used |
|
| 3 |
Not used |
|
| 4 |
BATT- |
Detects high voltage battery negative (-) pole terminal signal |
| 5 |
Not used |
|
| 6 |
Not used |
|
| 7 |
Not used |
|
| 8 |
VH0 |
Detects battery cell voltage signal |
| 9 |
VH2 |
Detects battery cell voltage signal |
| 10 |
VH4 |
Detects battery cell voltage signal |
| 11 |
VH6 |
Detects battery cell voltage signal |
| 12 |
VH8 |
Detects battery cell voltage signal |
| 13 |
Not used |
|
| 14 |
Not used |
|
| 15 |
BATT+ |
Detects high voltage battery positive (+) pole terminal signal |
| 16 |
Not used |
|
| 17 |
Not used |
|
| 18 |
Not used |
|
| 19 |
Not used |
|
| 20 |
Not used |
|
| 21 |
Not used |
|
| 22 |
Not used |
|
| Terminal number |
Terminal name |
Description |
| 23 |
VH1 |
Detects battery cell voltage signal |
| 24 |
VH3 |
Detects battery cell voltage signal |
| 25 |
VH5 |
Detects battery cell voltage signal |
| 26 |
VH7 |
Detects battery cell voltage signal |
| 27 |
VH9 |
Detects battery cell voltage signal |
| 28 |
Not used |
|
Battery Condition Monitor Module Connector B (28P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
VH11 |
Detects battery cell voltage signal |
| 2 |
VH13 |
Detects battery cell voltage signal |
| 3 |
VH15 |
Detects battery cell voltage signal |
| 4 |
VH17 |
Detects battery cell voltage signal |
| 5 |
VH19 |
Detects battery cell voltage signal |
| 6 |
Not used |
|
| 7 |
VH20 |
Detects battery cell voltage signal |
| 8 |
VH22 |
Detects battery cell voltage signal |
| 9 |
VH24 |
Detects battery cell voltage signal |
| 10 |
VH26 |
Detects battery cell voltage signal |
| 11 |
VH28 |
Detects battery cell voltage signal |
| 12 |
VH30-0 |
Detects battery cell voltage signal |
| 13 |
Not used |
|
| 14 |
Not used |
|
| 15 |
VH10 |
Detects battery cell voltage signal |
| 16 |
VH12 |
Detects battery cell voltage signal |
| 17 |
VH14 |
Detects battery cell voltage signal |
| 18 |
VH16 |
Detects battery cell voltage signal |
| 19 |
VH18 |
Detects battery cell voltage signal |
| 20 |
Not used |
|
| 21 |
Not used |
|
| 22 |
VH21 |
Detects battery cell voltage signal |
| 23 |
VH23 |
Detects battery cell voltage signal |
| Terminal number |
Terminal name |
Description |
| 24 |
VH25 |
Detects battery cell voltage signal |
| 25 |
VH27 |
Detects battery cell voltage signal |
| 26 |
VH29 |
Detects battery cell voltage signal |
| 27 |
Not used |
|
| 28 |
Not used |
|
Battery Condition Monitor Module Connector C (28P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
VH31 |
Detects battery cell voltage signal |
| 2 |
VH33 |
Detects battery cell voltage signal |
| 3 |
VH35 |
Detects battery cell voltage signal |
| 4 |
VH37 |
Detects battery cell voltage signal |
| 5 |
VH39 |
Detects battery cell voltage signal |
| 6 |
Not used |
|
| 7 |
VH40 |
Detects battery cell voltage signal |
| 8 |
VH42 |
Detects battery cell voltage signal |
| 9 |
VH44 |
Detects battery cell voltage signal |
| 10 |
VH46 |
Detects battery cell voltage signal |
| 11 |
VH48 |
Detects battery cell voltage signal |
| 12 |
Not used |
|
| 13 |
Not used |
|
| 14 |
Not used |
|
| 15 |
VH30-1 |
Detects battery cell voltage signal |
| 16 |
VH32 |
Detects battery cell voltage signal |
| 17 |
VH34 |
Detects battery cell voltage signal |
| 18 |
VH36-0 |
Detects battery cell voltage signal |
| 19 |
VH38 |
Detects battery cell voltage signal |
| 20 |
Not used |
|
| 21 |
Not used |
|
| 22 |
VH41 |
Detects battery cell voltage signal |
| 23 |
VH43 |
Detects battery cell voltage signal |
| 24 |
VH45 |
Detects battery cell voltage signal |
| Terminal number |
Terminal name |
Description |
| 25 |
VH47 |
Detects battery cell voltage signal |
| 26 |
VH49 |
Detects battery cell voltage signal |
| 27 |
Not used |
|
| 28 |
Not used |
|
Battery Condition Monitor Module Connector D (16P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
VH51 |
Detects battery cell voltage signal |
| 2 |
VH53 |
Detects battery cell voltage signal |
| 3 |
VH55 |
Detects battery cell voltage signal |
| 4 |
VH57 |
Detects battery cell voltage signal |
| 5 |
VH59 |
Detects battery cell voltage signal |
| 6 |
Not used |
|
| 7 |
Not used |
|
| 8 |
Not used |
|
| 9 |
VH50 |
Detects battery cell voltage signal |
| 10 |
VH52 |
Detects battery cell voltage signal |
| 11 |
VH54 |
Detects battery cell voltage signal |
| 12 |
VH56 |
Detects battery cell voltage signal |
| 13 |
VH58 |
Detects battery cell voltage signal |
| 14 |
VH60 |
Detects battery cell voltage signal |
| 15 |
Not used |
|
| 16 |
Not used |
|
Battery Condition Monitor Module Connector E (32P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
+B IGB |
Power source for battery condition monitor module (backup) |
| 2 |
IGB |
Power source for battery condition monitor module |
| 3 |
CNTPSIN |
Power source for contactors |
| 4 |
CNTP |
Drives high voltage contactor |
| 5 |
CNTN |
Drives high voltage sub contactor |
| 6 |
PRE |
Drives bypass contactor |
| 7 |
IG1MONI |
Detects IG1 signal |
| 8 |
F-CAN A_L |
Sends and receives F-CAN A communication signal (LOW) |
| 9 |
F-CAN A_H |
Sends and receives F-CAN A communication signal (HIGH) |
| 10 |
EP-CAN A_L |
Sends and receives EP-CAN communication signal (LOW) |
| 11 |
EP-CAN A_H |
Sends and receives EP-CAN communication signal (HIGH) |
| 12 |
Not used |
|
| 13 |
Not used |
|
| 14 |
NFAN |
Detects high voltage battery module fan revolution speed signal |
| 15 |
Not used |
|
| 16 |
Not used |
|
| 17 |
PG |
Ground for battery condition monitor module |
| 18 |
Not used |
|
| 19 |
IGHLDB |
Drives IGHLDB relay |
| 20 |
IGHLD |
Drives IGHLD1 relay |
| 21 |
IGHLD2 |
Drives battery fan relay |
| 22 |
Not used |
|
| 23 |
IGAMONI |
Detects IGA signal |
| 24 |
FANCTL |
Drives high voltage battery module fan |
| 25 |
Not used |
|
| 26 |
ISOC |
Detects battery current sensor signal (normal range) |
| 27 |
ISOCF |
Detects battery current sensor signal (fine range) |
| 28 |
VCCISOC |
Provides battery current sensor reference voltage |
| 29 |
SGISOC |
Sensor ground for battery current sensor |
| 30 |
CDS |
Detects collision detection signal from SRS unit |
| 31 |
Not used |
|
| 32 |
Not used |
|
Battery Condition Monitor Module Connector F (12P) (female terminals)
Courtesy of HONDA, U.S.A., INC.
|
| Terminal number |
Terminal name |
Description |
| 1 |
TBATT1 |
Detects high voltage battery module temperature sensor 1 signal |
| 2 |
TBATT3 |
Detects high voltage battery module temperature sensor 3 signal |
| 3 |
TBATT5 |
Detects high voltage battery module temperature sensor 5 signal |
| 4 |
Not used |
|
| 5 |
BATTIND1 |
Detects high voltage battery module identification resistor signal |
| 6 |
SGTB |
Sensor ground for high voltage battery module |
| 7 |
TBATT2 |
Detects high voltage battery module temperature sensor 2 signal |
| 8 |
TBATT4 |
Detects high voltage battery module temperature sensor 4 signal |
| 9 |
Not used |
|
| 10 |
Not used |
|
| 11 |
BATTIND2 |
Detects high voltage battery module identification resistor signal |
| 12 |
Not used |
|