Enable Conditions
| Condition |
Minimum |
Maximum |
| Engine coolant temperature [ECT Sensor 1] before EVAP purge control starts |
113 deg.F (45 deg.C) |
- |
12 volt battery voltage [Battery] |
10.5 V |
- |
| Fuel feed back |
Closed loop at stoichiometric |
[ ]: HDS Parameter