Home >> Honda >> 2021 >> Passport EX-L, AWD >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Mechanical / Engine Control System - Service, Testing And Troubleshooting >> Symptom Troubleshooting >> Auto Idle Stop System Symptom Troubleshooting - Starter System Counter Inspection (2024 2025)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Auto Idle Stop System Symptom Troubleshooting - Starter System Counter Inspection (2024 2025)

Auto Idle Stop System Description 

Starter System Counter Inspection 

NOTE:  This vehicle has a function to count the number of starter operations. If the starter operation exceeds the specified number, the auto idle stop system indicator (amber) blinks or the starter system indicator turns on, as a starter system warning message. To turn off the warning message, you must replace the parts that require maintenance and clear the starter counter.

  1. PGM-FI system check:

    - 1.Select the PGM-FI system with the HDS.

    - 2.Check for Pending or Confirmed DTCs with the HDS.

    DTC Description Confirmed DTC Pending DTC
         

    DTC (PGM-FI)

    Are any DTCs indicated?

    YES 

    Go to the indicated DTCs troubleshooting.

    NO 

    Go to step 2.

  2. Check the starter counter value with the HDS.

    - 2.Do the following procedures depending on the starter counter value.

    NOTICE: 

    Replacing parts and clearing the starter counter should always be done as a set.

    NOTE:  The HDS [IDLE STOP STARTER COUNTER CLEAR] has two types; select an appropriate command depending on the starter counter value.

    IDLE STOP STARTER COUNTER CHECK

    IDLE STOP STARTER COUNTER CLEAR

    Starter Counter Value (HDS [IDLE STOP STARTER COUNTER CHECK - Idling Stop Starter Counter] in the PGM-FI INSPECTION MENU) Parts that Need to be Replaced Starter Counter Clear(HDS [IDLE STOP STARTER COUNTER CLEAR] in the PGM-FI ADJUSTMENT MENU)
    Below 275, 000 times (Not needed) (Not needed)
    Above 275, 000 times Need to do

    Select the [Starter Counter B Clear]

    Is the work according to the starter counter value completed?

    YES 

    The starter counter system is OK.

    NO 

    Complete the procedures by replacing the appropriate parts and clearing the starter counter.