Run the Sensor Input Display Mode

1. Turn the vehicle to the OFF (LOCK) mode.

2. Press and hold both the AUTO button and RECIRCULATION CONTROL button, then start the engine.

3. After the engine starts, release both buttons. The display panel control unit will flash the sensor number then the value for that sensor. Record the value displayed.

4. To advance to the next sensor, touch the REAR WINDOW DEFOGGER/MIRROR DEFOGGER* button*: With mirror defogger 5. To cancel the sensor input display mode, press the AUTO button or turn the vehicle to the OFF (LOCK) mode.

Sensor ID Item  Displayed Value 
0 In-car temperature °C
1 Outside air temperature °C
2 Solar radiation sensor value: dark = 00, flashlight = 04, cloudy = 10, sunny = 65 10 kcal/m2 •h
3 Engine coolant temperature °C
4 Evaporator outlet air temperature (front) °C
5 Humidity value % (Relative Humidity)
6 A/C pressure value 0.1 MPa
8 Driver's air mix opening (low value indicates cooler air distribution, higher value indicates warmer air distribution) % of opening
9 Passenger's air mix opening (low value indicates cooler air distribution, higher value indicates warmer air distribution) % of opening
10 Rear air mix opening (low value indicates cooler air distribution, higher value indicates warmer air distribution) % of opening
13 Recirculation control opening % of opening
15 Vehicle speed (vehicle must be driven to display speed) km/h
16 Vent temperature air out (Fr TAO) °C
19 Evaporator outlet air temperature (rear) °C
20 Humidity value °C of dew point
21 Fog margin °C
22 Solar radiation azimuth Angle
23 Solar radiation angle of elevation Angle
24 Rear vent temperature air out (Rr TAO) °C
25 Mode control motor A positioning %
26 Mode control motor B positioning %
27 Rear mode control motor positioning %
28 A/C compressor variable capacity control solenoid detect electric current value (VDC Current) 0.01 A

Celsius to Fahrenheit Conversion Table 

°C °F °C °F °C °F °C °F °C °F
0 32 10 50 20 68 30 86 40 104
1 34 11 52 21 70 31 88 41 106
2 36 12 54 22 72 32 90 42 108
3 37 13 55 23 73 33 91 43 109
4 39 14 57 24 75 34 93 44 111
5 41 15 59 25 77 35 95 45 113
6 43 16 61 26 79 36 97 46 115
7 45 17 63 27 81 37 99 47 117
8 46 18 64 28 82 38 100 48 118
9 48 19 66 29 84 39 102 49 120
°C °F °C °F °C °F °C °F °C °F
50 122 60 140 70 158 80 176 90 194
51 124 61 142 71 160 81 178 91 196
52 126 62 144 72 162 82 180 92 198
53 127 63 145 73 163 83 181 93 199
54 129 64 147 74 165 84 183 94 201
55 131 65 149 75 167 85 185 95 203
56 133 66 151 76 169 86 187 96 205
57 135 67 153 77 171 87 189 97 207
58 136 68 154 78 172 88 190 98 208
59 138 69 156 79 174 89 192 99 210

Alphanumeric Conversion Table 

Display Reading (Alphanumeric) °C °F %
A1 thru A9 -1 thru -9 30 thru 16 -1 thru -9
B0 thru B9 -10 thru -19 14 thru -2 -10 thru -19
C0 thru C9 -20 thru -29 -4 thru -20 -20 thru -29
D0 thru D9 -30 thru -39 -22 thru -38 -30 thru -39
E0 thru E9 -40 thru -49 -40 thru -56 -40 thru -49
E9 -50 or less -58 or less -50 or less
F0 thru F9 100 thru 109 212 thru 228 100 thru 109
F9 110 or more 230 or more 110 or more

Alphanumeric Conversion Table (Mode Control Motor A Positioning) 

Display Reading (Percent) Mode Position
0 VENT
50 HEAT/VENT-1
50 HEAT/VENT-2
100 HEAT
100 HEAT/DEF-1
100 HEAT/DEF-2
100 DEF

Alphanumeric Conversion Table (Mode Control Motor B Positioning) 

Display Reading (Percent) Mode Position
0 VENT
0 HEAT/VENT-1
50 HEAT/VENT-2
24.7 HEAT
57 HEAT/DEF-1
73 HEAT/DEF-2
100 DEF

Alphanumeric Conversion Table (Rear Mode Positioning) 

Display Reading (Percent) Mode Position
0 VENT
50 HEAT/VENT
100 HEAT