DTC B1280 (Body Control Module): Inspection
L_TURN_SW, R_TURN_SW Shorted Wire Inspection
Test Procedure
- Preparation
- Body control module connector A (66P): disconnected
- Combination light switch connector (12P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) Body control module connector A (66P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| L_TURN_SW, R_TURN_SW shorted wire to wire inspection | OFF | There is more than 1 MOhms | ||
| L_TURN_SW shorted to ground inspection | OFF | There is more than 1 MOhms | ||
| R_TURN_SW shorted to ground inspection | OFF | There is more than 1 MOhms | ||
Results
- If abnormal, there is a problem in the circuit.
Body Control Module Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining body control module is the cause.
Results
- There is a problem with the body control module.