Keyless Buzzer Circuit Troubleshooting: Inspection
SMART_BUZZER, GND Circuit Inspection
Test Procedure
- Preparation
- Keyless buzzer connector (3P): disconnected
- Body control module connector B (66P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) Keyless buzzer connector (3P) female terminals | (Disconnected) Body control module connector B (66P) female terminals |
| IG Mode |
|
|
Normal Conditions | ||
| SMART_BUZZER open wire inspection | OFF | There is less than 1 Ohms | |||
| GND open wire inspection | OFF | There is less than 1 Ohms | |||
| SMART_BUZZER shorted to ground inspection | OFF | There is more than 1 MOhms | |||
Results
- If it is abnormal, there is a problem in the circuit.
Keyless Buzzer Inspection
NOTE: Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.
Test Procedure
- Install a known-good keyless buzzer and attempt to reproduce the failure.
Results
- If the failure is reproduced, there is a problem with other related components.
- If the symptom/DTC goes away, the keyless buzzer must be faulty.
Body Control Module Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining body control module is the cause.
Results
- There is a problem with the body control module.