Keyless Buzzer Circuit Troubleshooting: Inspection

SMART_BUZZER, GND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Keyless buzzer connector (3P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582371Courtesy of HONDA, U.S.A., INC.

GHH582372Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  SMART_BUZZER open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  SMART_BUZZER shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

Keyless Buzzer Inspection 

NOTE:  Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.

Test Procedure 

Results 

Body Control Module Inspection 

Test Procedure 