PCM Power and Ground Circuit Troubleshooting: Inspection
+B_BACKUP_FI-ECU, FI_ECU_GND Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- -
PCM connector A (50P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected)PCM connector A (50P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| +B_BACKUP_FI-ECU circuit inspection | OFF | 12 V battery voltage [circuit type 1] | ||
| FI_ECU_GND open wire inspection | OFF | There is less than 1 Ohm |
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
+B_IGP Circuit Inspection
Test Procedure
- Preparation
- -
PGM-FI main relay 1: disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected) PGM-FI main relay 1 socket (4P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| +B_IGP circuit inspection 1 | OFF | 12 V battery voltage [circuit type 1] | ||
| OFF |
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
FI_MAIN_RLY_OUT, FI_MAIN_RLY_CL- Open Wire Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- -
PGM-FI main relay 1: disconnected
- -
PCM connector A (50P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected) PGM-FI main relay 1 socket (4P) female terminals | (Disconnected) PCM connector A (50P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| FI_MAIN_RLY_OUT open wire inspection | OFF | There is less than 1 Ohm | |||
| FI_MAIN_RLY_CL- open wire inspection | OFF | There is less than 1 Ohm | |||
Results
- If abnormal, there is a problem in the circuit.
IG1(MONI), GND2, PG, PG(COIL) Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- -
PCM connector E (80P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected) PCM connector E (80P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| IG1(MONI) circuit inspection | ON | 12 V battery voltage [circuit type 1] | ||
| GND2 open wire inspection | OFF | There is less than 1 Ohm | ||
| PG open wire inspection | OFF | There is less than 1 Ohm | ||
| PG(COIL) open wire inspection | OFF | There is less than 1 Ohm | ||
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
IG1_FUEL_PUMP, FUEL_PUMP_RLY_OUT Circuit Inspection
Test Procedure
- Preparation
- -
PGM-FI main relay 2: disconnected
- -
Fuel tank unit connector (4P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected) PGM-FI main relay 2 socket (4P) female terminals | (Disconnected) Fuel tank unit connector (4P) female terminals |
| IG Mode |
|
|
Normal Conditions | ||
| IG1_FUEL_PUMP circuit inspection | ON | 12 V battery voltage [circuit type 1] | |||
| FUEL_PUMP_RLY_OUT open wire inspection | OFF | There is less than 1 Ohm | |||
| FUEL_PUMP_RLY_OUT shorted to ground inspection | OFF | There is more than 1 MOhm | |||
Results
- If it is abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
FI_MAIN_RLY_OUT Shorted Wire Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
-
- -
PGM-FI main relay 1: disconnected
- -
PGM-FI main relay 2: disconnected
- -
Each injector connector (2P): disconnected
- -
PCM connector A (50P): disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
| (Disconnected) PGM-FI main relay 1 socket (4P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| FI_MAIN_RLY_OUT shorted to ground inspection | OFF | There is more than 1 MOhm |
Results
- If abnormal, there is a problem in the circuit.
Components Connected to FI_MAIN_RLY_OUT Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Preconditions
This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
- -
PGM-FI main relay 1: disconnected
- -
PGM-FI main relay 2: disconnected
- -
Each injector connector (2P): disconnected
- -
PCM connector A (50P): disconnected
- -
- Procedure
Perform the inspection according to the following table and while reconnecting these parts or connectors, one at a time:
- -
PGM-FI main relay 2
- -
Each injector connector (2P)
- -
PCM connector A (50P)
- -
| (Disconnected) PGM-FI main relay 1 socket (4P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| Unit internal circuit inspection | OFF | Not shorted | ||
Results
- If it is abnormal, there is a problem with the component that caused the short to return when it was reconnected.
Fuel Pump Inspection
Preconditions
This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
- -
PGM-FI main relay 2: disconnected
- -
- Procedure
- -
Perform the inspection according to the following table.
- -
| (Disconnected) PGM-FI main relay 2 socket (4P) female terminals |
| IG Mode |
|
Normal Conditions | ||
| Unit internal circuit inspection | OFF | Not shorted | ||
Results
- If it is normal, there is a problem with the fuel pump.
PCM Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.