Home >> Honda >> 2024 >> Pilot EX-L, AWD >> Repair and Diagnosis >> Accessories & Equipment >> Anti-Theft Systems >> Security System / Keyless Entry System - Testing & Troubleshooting >> Troubleshooting >> Keyless/Power Door Locks/Security System Symptom Troubleshooting - Security alarm system will not arm >> Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Keyless/Power Door Locks/Security System Symptom Troubleshooting - Security alarm system will not arm: Inspection

HOOD_SW, HOOD_SW_2, GND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Left hood latch switch connector (2P) female terminals (Disconnected) Relay control module connector C (18P) female terminals  
    IG Mode
GHH582397Courtesy of HONDA, U.S.A., INC.

GHH582398Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  HOOD_SW open wire inspection  OFF There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  HOOD_SW shorted to ground inspection  OFF   There is more than 1 MOhms 
           
      (Disconnected) Right hood latch switch connector (2P) female terminals (Disconnected) Left hood latch switch connector (2P) female terminals  
    IG Mode
GHH582401Courtesy of HONDA, U.S.A., INC.

GHH582402Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  HOOD_SW_2 open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  HOOD_SW_2 shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

FL_DOOR_SW, GND Open Wire Inspection 

Test Procedure 

           
      (Disconnected) Driver's door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582406Courtesy of HONDA, U.S.A., INC.

GHH582407Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  FL_DOOR_SW open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 

Results 

DR_SILCON_UNLOCK, GND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Driver's door latch connector (10P) female terminals (Disconnected) Driver's door control unit connector C (32P) female terminals  
    IG Mode
GHH582410Courtesy of HONDA, U.S.A., INC.

GHH582411Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  DR_SILCON_UNLOCK open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  DR_SILCON_UNLOCK shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

DR_KEY_CYL_LOCK, GND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Driver's door latch connector (10P) female terminals (Disconnected) Driver's door control unit connector C (32P) female terminals  
    IG Mode
GHH582415Courtesy of HONDA, U.S.A., INC.

GHH582416Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  DR_KEY_CYL_LOCK open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  DR_KEY_CYL_LOCK shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

FR_DOOR_SW, GND Open Wire Inspection 

Test Procedure 

           
      (Disconnected) Front passenger's door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582420Courtesy of HONDA, U.S.A., INC.

GHH582421Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  FR_DOOR_SW open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 

Results 

AS_SILCON_UNLOCK, GND Circuit Inspection 

Test Procedure 

      (Disconnected) Front passenger's door latch connector (10P) female terminals (Disconnected) Front passenger's door control unit connector C (32P) female terminals  
    IG Mode
GHH582424Courtesy of HONDA, U.S.A., INC.

GHH582425Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  AS_SILCON_UNLOCK open wire inspection  OFF There is less than 1 Ohms 
  GND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  AS_SILCON_UNLOCK shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

RL_DOOR_SW, SGND Open Wire Inspection 

Test Procedure 

           
      (Disconnected) Left rear door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582429Courtesy of HONDA, U.S.A., INC.

GHH582430Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  RL_DOOR_SW open wire inspection  OFF There is less than 1 Ohms 
  SGND open wire inspection  OFF   There is less than 1 Ohms 

Results 

RR_L_SILCON_UNLOCK, SGND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Left rear door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582433Courtesy of HONDA, U.S.A., INC.

GHH582434Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  RR_L_SILCON_UNLOCK open wire inspection  OFF There is less than 1 Ohms 
  SGND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  RR_L_SILCON_UNLOCK shorted to ground inspection  OFF   There is more than 1 MOhms 

Results 

RR_DOOR_SW, SGND Open Wire Inspection 

Test Procedure 

           
      (Disconnected) Right rear door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582438Courtesy of HONDA, U.S.A., INC.

GHH582439Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  RR_AS_DOOR_SW open wire inspection  OFF There is less than 1 Ohms 
  SGND open wire inspection  OFF   There is less than 1 Ohms 

Results 

RR_R_SILCON_UNLOCK, SGND Circuit Inspection 

Test Procedure 

           
      (Disconnected) Right rear door latch connector (10P) female terminals (Disconnected) Body control module connector B (66P) female terminals  
    IG Mode
GHH582442Courtesy of HONDA, U.S.A., INC.

GHH582443Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  RR_R_SILCON_UNLOCK open wire inspection  OFF There is less than 1 Ohms 
  SGND open wire inspection  OFF   There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  RR_R_SILCON_UNLOCK shorted to ground inspection  OFF   There is more than 1 MOhms 
   

Results 

Relay Control Module Inspection 

NOTE:  Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.

Test Procedure 

Results 

Body Control Module Inspection 

Test Procedure 

Results