DTC B1038 (Body Control Module): Inspection
BF-CAN_H, BF-CAN_L Open Wire Inspection
Test Procedure
- Preparation
- CAN gateway connector (40P): disconnected
- Body control module connector A (66P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) CAN gateway connector (40P) female terminals | (Disconnected) Body control module connector A (66P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| BF-CAN_H open wire inspection | OFF | There is less than 1 Ohms | |||
| BF-CAN_L open wire inspection | OFF | There is less than 1 Ohms | |||
Results
- If abnormal, there is a problem in the circuit.
VF-CAN A_H, VF-CAN A_L Open Wire Inspection
Test Procedure
- Preparation
- CAN gateway connector (40P): disconnected
- VSA modulator-control unit connector (46P): disconnected
- Procedure
- Perform the inspection according to the following chart.
| (Disconnected) CAN gateway connector (40P) female terminals | (Disconnected) VSA modulator-control unit connector (46P) female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| VF-CAN A_H open wire inspection | OFF | There is less than 1 Ohms | |||
| VF-CAN A_L open wire inspection | OFF | There is less than 1 Ohms | |||
Results
- If abnormal, there is a problem in the circuit.
Body Control Module Inspection
Preconditions
NOTE: This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Procedure
- Do the HDS [F-CAN Bus Connected Unit Check].
- Normal Conditions
- The HDS indicates body control module is Detected on BF-CAN.
Results
- If it is abnormal, there is a problem with the body control module.
VSA modulator-control unit Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining VSA modulator-control unit is the cause.
Results
- There is a problem with the VSA modulator-control unit.