Circuit Description
The cam phasing system is a hydraulically actuated phase shifting mechanism. The powertrain control module (PCM) supplies the ignition positive driver and ground circuits. A pulse width modulated (PWM) driver controls the amount that the camshaft actuator solenoid assembly advances or retards the exhaust camshaft. The exhaust camshaft is commanded to a maximum retard position of 25 degrees. When the exhaust camshaft is retarded at the maximum rate, the duty cycle of the signal is at 100 percent. The maximum advance rate has a 0 percent duty cycle. Other than when the camshaft is at full advance, a 50 percent duty cycle is used to maintain a steady retard angle.
If the desired and actual cam phase angle error exceeds its tolerance value for a certain amount of time, then DTC P0014 will set.