Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the generator.
- Ignition ON, GEN L-Terminal Signal Command 0%, test for less than 1 volt between the generator turn on signal circuit terminal 1 and ground.
- If greater than the specified range, test the generator turn on signal circuit for a short to voltage. If the circuit tests normal, replace the GBCM.
- Command the GEN L-Terminal Signal ON to 80% duty cycle with a scan tool. Test for 3.0 volts between the generator turn on signal circuit terminal 1 and ground.
- If less than the specified range, test the generator turn on signal circuit for a short to ground, or an open/high resistance. If the circuit tests normal, replace the GBCM.
- If the circuit tests normal, replace the generator.