Circuit/System Testing
- Verify the integrity of the entire air induction system by inspecting for the following conditions:
- Any damaged components
- Loose or improper installation
- An air flow restriction
- Any vacuum leak
- Improperly routed vacuum hoses
- In cold climates, inspect for any snow or ice buildup
- Verify that restrictions do not exist in the MAP sensor port or vacuum source.
- Ignition OFF, disconnect the harness connector at the MAP sensor.
- Ignition OFF for 90 seconds, test for less than 5 ohms between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 1 and ground.
- If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool MAP Sensor parameter is less than 1 kPa.
- If greater than the specified range, test the signal circuit terminal 3 for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the signal circuit terminal 3 and the 5-volt reference circuit terminal 1. Verify the scan tool MAP Sensor parameter is greater than 126 kPa.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If the circuits test normal, test or replace the MAP sensor.