Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the FTP sensor.
- Ignition OFF, test for less than 5 Ω between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, test for 4.8-5.2V between the 5V reference circuit terminal 3 and ground.
- If less than the specified range, test the 5V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If greater than the specified range, test the 5V reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Verify the scan tool FTP sensor parameter is less than 0.1V.
- If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3A fused jumper wire between the signal circuit terminal 1 and the 5V reference circuit terminal 3. Verify the scan tool FTP sensor parameter is greater than 4.7V.
- If less than the specified range, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the FTP sensor.