General Service Specifications: Specifications
COOLING SYSTEM SPECIFICATIONS
| Model | Specification | ||
|---|---|---|---|
| Cooling System Capacity | 1.7 Gal (6.5 L) | ||
| Pressure Relief Cap Opening Pressure | 12.5-18 psi. (86-124.5 kPa) | ||
| Thermostat Opens | |||
| Starts | 177°F (82°C) | ||
| Fully Open | 205°F (95°C) | ||
THERMOSTAT R & I
Refer to THERMOSTAT .
WATER PUMP R & I
Refer to ENGINE COOLANT PUMP .