Component Inspection
- Ignition "OFF".
- Disconnect Fuel Tank Unit connector.
- Measure resistance between terminal 1 and 2 of the Fuel Temperature Sensor connector (To Component Side).RESISTANCE REFERENCE CHART
Fuel temperature sensor Normal Parameter Temperature (°C/°F) 0°C (32°F) 20°C (68°F) 40°C (104°F) 80°C (176°F) Resistance (kΩ) 4~7 kΩ 2~3 kΩ 0.9~1.3 kΩ 0.2~0.4 kΩ - Is the measured resistance of FTS within specifications?
YES
- Substitute with a known - good PCM and check for proper operation.
If the problem is corrected, replace PCM and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO
- Substitute with a known - good FTS and check for proper operation.
If the problem is corrected, replace FTS and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
- Substitute with a known - good PCM and check for proper operation.