DTC Troubleshooting Procedures
>>
DTC P0112: Intake Air Temperature Low Input
>>
Specification
April 5, 2026:
LEMON Manuals is launched!
Read the announcement.
DTC P0112: Intake Air Temperature Low Input: Specification
INTAKE AIR TEMPERATURE SENSOR SPECIFICATION
Normal Parameter
20°C (68°F)
40°C (104°F)
80°C (176°F)
Signal Resistance & Voltage
2.0~3.0 kΩ
3.3~3.7V
0.7~1.6 kΩ
2.5~2.9V
0.2~0.4 kΩ
1.0~1.4V