General Service Specifications: Specifications
COOLING SYSTEM SPECIFICATIONS
| Model | Specification | |
|---|---|---|
| Cooling System Capacity | ||
| 2.4L & 2.7L | 1.8 Gal (7.0 L) | |
| 3.5L | 2.9 Gal (11.0L) | |
| Pressure Relief Cap Opening Pressure | 13-18 psi (93-123 kPa) | |
| Thermostat Opens | ||
| Starts | 176-183°F (80-84°C) | |
| Fully Open | 203°F (95°C) | |
THERMOSTAT R & I
- For 2.4L, refer to THERMOSTAT .
- For 2.7L, refer to THERMOSTAT .
- For 3.5L, refer to THERMOSTAT .
WATER PUMP R & I
- For 2.4L, refer to ENGINE COOLANT PUMP .
- For 2.7L, refer to ENGINE COOLANT PUMP .
- For 3.5L, refer to ENGINE COOLANT PUMP .