General Service Specifications: Specifications
COOLING SYSTEM SPECIFICATIONS
| Model | Specification | ||
|---|---|---|---|
| Cooling System Capacity | |||
| 2.0L | 1.6 Gal (6.0 L) | ||
| 2.7L | 1.8 Gal (7.0 L) | ||
| Pressure Relief Cap Opening Pressure | |||
| 2.0L | 12-16 psi (83-110 kPa) | ||
| 2.7L | 13.51-17.77 psi (93.2-122.6 kPa) | ||
| Thermostat Opens | |||
| Starts | 180°F (82°C) | ||
| Fully Open | 203°F (95°C) | ||
THERMOSTAT R & I
For 2.0L, refer to THERMOSTAT . For 2.7L, refer to THERMOSTAT .
WATER PUMP R & I
For 2.0L, refer to ENGINE COOLANT PUMP . For 2.7L, refer to ENGINE COOLANT PUMP .