SENSORS Mass Air Flow Sensor (MAFS) Type Hot film type
Output Voltage Idle: 0.6 ~ 1.0V
2000 rpm: 1.3 ~ 1.5V
3000 rpm: 1.7 ~ 1.9 V
Intake Air Temperature Sensor (IATS) Type Thermistor type (built in MAFS)
Resistance -20°C (-4°F) 11.72 ~ 19.54 kohm
0°C (32°F) 4.75 ~ 7.11 kohm
20°C (68°F) 2.22 ~ 2.82 kohm
40°C (104°F) 1.06 ~ 1.31 kohm
60°(140°F) 0.55 ~ 0.66 kohm
80°C (176°F) 0.30 ~ 0.36 kohm
Engine Coolant Temperature Sensor (ECTS) Type Thermistor type
Resistance -40°C (-40°F) 48.14 kohm
-20°C (-4°F) 14.13~16.83 kohm
0°C (32°F) 5.79 kohm
20°C (68°F) 2.31 ~ 2.59 kohm
40°C (104°F) 1.15 kohm
60°C (140°F) 0.59 kohm
80°C (176°F) 0.32 kohm
SENSOR Throttle Position Sensor (TPS) Type Variable Resistor Type
Resistance 1.6 ~ 2.4 kohm
Output Voltage C.T 0.2 ~ 0.8 V
W.O.T 4.3 ~ 4.8 V
Heated Oxygen Sensor (HO2S) Type Zirconia Sensor (including Heater)
Output Voltage 0 ~ 1V
Heater Resistance 3.0 ~ 4.0ohm at 23+/-5°C
Knock Sensor Type Piezo-electric type
Capacitance 0.8 ~ 1.6 nF
Camshaft Position Sensor (CMPS) Type Hall Effect Sensor
Output Voltage 0 ~ 5.0V
Crankshaft Position Sensor (CKPS) Type Hall Effect Sensor
Output Voltage 0 ~ 5.0V
Fuel Tank Pressure Sensor (FTPS) Type Piezo-Resistivity type
Output Voltage Approx. 2.5V at idle
ACTUATORS Injector Type Electromagnetic Type
Number 6
Coil Resistance 13.8 ~ 15.2 ohm at 20°C
Purge Control Solenoid Valve (PCSV) Type Duty Control Type
Coil Resistance 24.5 ~ 27.5 ohm at 20°C
Idle Speed Control Actuator (ISCA) Type Double Coil Type
Coil Resistance CLOSE 17.0 ~ 18.2 ohm (at 20 °C)
OPEN 14.9 ~ 16.1 ohm (at 20 °C)
Ignition Coil Type Mold Coil type
Primary Coil 0.74+/-10% ohm
Secondary Coil 13.3+/-15% kohm
Canister Close Valve (CCV) Type ON/OFF Control type
Resistance 23.9 ~ 26.9ohm at 20°C (68°F)