Signal Circuit Inspection
- IG "OFF".
- Disconnect HO2S (B1/S1) connector.
- IG "ON" & ENG "OFF".
- Measure voltage between terminal 2 of HO2S (B1/S1) and chassis ground.
Specification: Approx. 0.45V
- Is the measured voltage within specification?
YES : --> Go to "Ground Circuit Inspection" procedure.
NO : --> Repair or replace as necessary and then, go to "VERIFICATION OF VEHICLE REPAIR " procedure.