Shift Lever: Adjustment
Adjusting method for the control cable
- Set room side lever and T/M side lever (A) to "N" position.
- Connect the room side lever and shift cable, (refer to INSTALLATION )
- Connect the T/M side lever (A) to cable (B) in this following order;
- Push the cable (B) lightly to "F" direction shown to eliminate FREE PLAY of the cable (B).
- Tighten the adjusting nut (C).
- After adjusting the cable (B) according to procedure no. 2-3, check to be sure that this part operates surely at each range of T/M side corresponding to each position of room lever.