LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2007 >> Elantra GLS, Standard >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Fuel System (G4GC-GSL 2.0) >> DTC Troubleshooting Procedures >> DTC P2414 Ho2S Exhaust Sample Error (Bank 1/Sensor 1) >> DTC Detecting Condition
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P2414 Ho2S Exhaust Sample Error (Bank 1/Sensor 1): DTC Detecting Condition

DTC DETECTING CONDITION CHART

Item Detecting Condition Detecting Condition
DTC Strategy
  • Sensor not mounted - Plausibility check in Part load or Full load
  • Poor connection or damaged harness
  • Front HO2S
Enable Conditions
  • Sensor tip temp. > 650°C (1202°F)
  • Part load or full load
  • 11V < Battery voltage < 16V
  • No relevant failure
Threshold Value
  • 3.2 V < HO2S < 4.8 V
Diagnostic Time
  • 30 sec.
MIL On Condition
  • 2 Driving Cycles